Locate LED Does Not Turn on During Chassis Lamp Test
(6713569, 6711416)
When running ILOM 2.0.3.3, if you press the locate button more than 5 seconds to
initiate the lamp LED test, the LED does not turn on and a “
transition to
degraded
” message appears in the SEL log.
Issues Specific to ILOM 2.0.3.2
The issues in this section are specific to the ILOM 2.0.3.2 on the Sun Blade 6048
modular system.
The
stop /CH
Command in ILOM 2.0.3.2 is Different
Than in ILOM 2.0.3.1 (6679679)
The following commands have new functionality for ILOM 2.0.3.2:
■
stop /CH
This command now defaults to graceful shutdown, instead of a forced shutdown,
of the system. The CMM will attempt to contact all the server modules and shut
them down gracefully. If it cannot shut the server modules down, it reports back
an error.
■
stop /CH -force
This command causes a forced shutdown, which is the same as the ILOM 2.0.3.1
version of
stop /CH
.
General ILOM Issues
The following issues are not specific to one ILOM version.
/CH/LOCATE Does Not Turn Off When Set to ON
Using the ILOM CLI or ipmitool (6695802)
/CH/LOCATE does not turn off when set to ON/Fast_Blink using ipmitool or CLI.
However, when the chassis Locate LED button is pressed, it times out and goes off
after 30 minutes as expected.
Summary of Contents for Sun Blade 6048
Page 1: ...Sun Blade 6048 Modular System Product Notes Part No E23072 01 April 2011...
Page 12: ...4 Sun Blade 6048 Modular System Product Notes April 2011...
Page 39: ...Chapter 3 ILOM Notes and Issues 31...
Page 40: ...32 Sun Blade 6048 Modular System Product Notes April 2011...
Page 42: ...34 Sun Blade 6048 Modular System Product Notes April 2011...