Chapter 3
ILOM Notes and Issues
21
SP Login Through Web GUI Fails After a New IP
Address Is Assigned (6745118)
If you change the CMM IP address in the SP web GUI, you cannot log into the web
GUI using the new IP address. You can log into the CLI interface.
Workaround
If you change the CMM IP address in the web GUI, log into the CLI to reconfigure
the IP address again. then log into the web GUI with the new IP address.
For more information on configuring the IP address in the web GUI, refer to the
Sun
Integrated Lights Out Manager 2.0 User’s Guide
.
SP Reports Incorrect FM, NEM, and Server Module
Removal and Insertion Events (6744044)
The SP reports fan module (FM), network express module (NEM), and server
module blade (BL) removal and insertion event logs repeatedly, though no insertion
or removal has taken place.
The Tempfail LED and Service LED On the Rear of the
Chassis Functionality Is Switched (6745875)
When one FM or one PSU is removed from the Sun Blade 6048 chassis, the Tempfail
LED on the rear panel turns on while the Service LED on the rear panel is off. The
Service LED on the front panel turns on, which is the correct behavior.
When the FM or PSU is reinserted, the Tempfail LED on the rear turns off, and the
Service LED on the front turns off.