Ultra Enterprise 3000 System Installation Guide—May 1996
2
Figure 2-5
Connecting Twisted Pair Ethernet to N-type Coaxial Cable
Table 2-1 lists the cabling limitations for Ethernet.
1. Finite lengths (as constrained by transmission line phenomena). Minimum length = 23.4M; maximum = 500M.
If cable falls shorter than one of these values, add cable to achieve next-highest value.
2. Transceivers are placed at intervals of 2.5 meters, or multiples of 2.5 meters along the Ethernet cable.
Example: transceivers are connected 2.5 meters apart, not 2.0 meters.
Example: transceivers are connected 15 meters apart (6 multiples of 2.5 meters), not 14.0 meters.
Table 2-1
Ethernet Cabling Limitations for N-type Coaxial Cable
Cable Segment
Length in Meters
Allowed contiguous length of cable segments
23.4
70.2
117.0
500.0
1
Distance between transceivers (multiples-of)
2.5
2
Minimum length of Ethernet coaxial cable segments
23.4
Maximum length of transceiver “drop” cable
50.0
Minimum length of twisted pair cable
no minimum
Maximum length of twisted pair cable
110
Transceiver
Vampire tap or N-type connectors
Ethernet cable
Transceiver drop cable
(coaxial or optical fiber)
Hardware interface
10/100BASE-T
twisted-pair cable
Server
Summary of Contents for Ultra Enterprise 3000
Page 6: ...vi Ultra Enterprise 3000 System Installation Guide May 1996 Figure 3 4 System Status LEDs 3 7 ...
Page 8: ...viii Ultra Enterprise 3000 System Installation Guide May 1996 ...
Page 14: ...xiv Ultra Enterprise 3000 System Installation Guide May 1996 ...
Page 22: ...1 8 Ultra Enterprise 3000 System Installation Guide May 1996 1 ...
Page 34: ...2 12 Ultra Enterprise 3000 System Installation Guide May 1996 2 ...
Page 44: ...4 2 Ultra Enterprise 3000 System Installation Guide May 1996 4 ...
Page 47: ...Index 3 U unpacking 1 2 W warnings notes cautions xiii ...
Page 48: ...Index 4 Ultra Enterprise 3000 System Installation Guide May 1996 ...