72
Sun Fire V210 and V240 Servers Administration Guide • April 2003
CODE EXAMPLE 6-7
prtdiag
Command Output
In addition to the information in
CODE EXAMPLE 6-7
,
prtdiag
with the verbose
option (
-v
) also reports on front panel status, disk status, fan status, power supplies,
hardware revisions, and system temperatures.
CODE EXAMPLE 6-8
prtdiag
Verbose Output
In the event of an overtemperature condition,
prtdiag
reports an error in the Status
column.
CODE EXAMPLE 6-9
prtdiag
Overtemperature Indication Output
Similarly, if there is a failure of a particular component,
prtdiag
reports a fault in
the appropriate Status column.
CODE EXAMPLE 6-10
prtdiag
Fault Indication Output
System Temperatures (Celsius):
-------------------------------
Device
Temperature
Status
---------------------------------------
CPU0 59 OK
CPU2 64 OK
DBP0 22 OK
System Temperatures (Celsius):
-------------------------------
Device
Temperature
Status
---------------------------------------
CPU0
62
OK
CPU1
102
ERROR
Fan Status:
-----------
Bank RPM Status
---- ----- ------
CPU0 4166 [NO_FAULT]
CPU1 0000 [FAULT]
Summary of Contents for Fire V240
Page 8: ...Figures viii FIGURE 6 5 watch net all Diagnostic Output Message 80 80...
Page 34: ...20 Sun Fire V210 and V240 Servers Administration Guide April 2003...
Page 50: ...36 Sun Fire V210 and V240 Servers Administration Guide April 2003...
Page 60: ...46 Sun Fire V210 and V240 Servers Administration Guide April 2003...
Page 66: ...52 Sun Fire V210 and V240 Servers Administration Guide April 2003...
Page 102: ...88 Sun Fire V210 and V240 Servers Administration Guide April 2003...