Important: These entire instructions must be read.

Cautions

These entir

e instructions must be read to ensure the best

possible operation and safest use of the furnace.
Manufacturer’s recommendations and codes set down
by regulating authorities must be followed when installing
and operating the furnace. All oil burning furnaces manu-
factured by Trent Metals Limited have been tested for
safety by the Canadian Standards Association
Laboratories and carry their certificate of approval which
is recognized by Insurance Underwriters of Canada.

Cautions

Do not stor

e combustibles within minimum installation

clearances.

Do not attempt to start the burner when excess oil has
accumulated, when furnace is full of vapour, or when the
chamber is very hot.

Do not start the burner unless the blower access door is
secured in place.

Do not tamper with the unit or controls - call your service
man.

Never burn garbage or paper in the heating system, and
never leave paper or rags around the unit.

Do not clean combustion chamber.

Fur

nace Maintenance and Care

Oil Blower Motor - wher

e oil cups are provided at least

twice a year with No.20 Auto oil, 4 or 5 drops for each
cup. Do not over oil. Do not oil blower bearings.

Contact your installer or serviceman on any service prob-
lems or replacement parts.

Clean air filters, located in the blower section of the fur-
nace, at least once a month and replace with new filters
(if disposable type used), twice a year. Use disposable or
permanent type filters.
See specification sheet for sizes required.
Your Summeraire furnace should be checked and serv-
iced at least once a year by a licenced burner mechanic.

As part of this annual service, ensure the flue pipe(s) are
cleaned, inspected and if required they should be
replaced.

How to start your oil fur

nace

The operation of the oil bur

ner is entirely automatic. To

start it, set the room thermostat above room tempera-
ture. The oil burner will start automatically. If the burner
fails to start check the following:

1. Make sure valve at oil tank is open to allow oil to burner.

2. Make sure “Furnace” switch is “ON”. This switch is

usually mounted in a convenient location on a wall or
partition near the furnace.

3. Check electrical service panel and make sure breaker

is not tripped or fuse is blown - Replace with correct
amperage fuse only.

4. If item 1, 2, and 3 are okay, press “RESET” button on

oil burner ONCE ONLY.

5. If unit fails to start call a qualified service man.

Note:

If your fur

nace is to be shut down for an extended period

of time, oil valve at oil tank must be closed. Before
restarting your furnace, be sure to turn oil valve on.
Proceed to instructions on “How To Start Your Oil
Furnace”. If unit fails to start, call a qualified service man.

To maintain maximum operating efficiency and comfort
from your Summeraire Furnace, it should be serviced at
least once a year by a licenced burner mechanic. The fol-
lowing maintenance procedures should be performed by
the service man.

1. Heat exchanger and combustion chamber should be

checked for any type of damage or abnormal wear.

2. Blower and fan assembly should be checked for

lubrication, belt condition, pulley wear and alignment.

3. Set up burner using combustion testing equipment

to “0” smoke.

4. Change oil filter cartridge (in oil filter at oil tank).

5. Replace oil nozzle with one specified for unit.

6. Check operation of limit control.

F-RME-INSMAN-EN-REV1

Summary of Contents for RME 111

Page 1: ...OTE THIS FURNACE IS IN COMPLIANCE WITH THE CSA STANDARD B140 0 03 BLOCKED FLUE THEREFORE THE BLOCKED VENT SAFETY SWITCH MODEL WMO 1 SUPPLIED WITH THIS FURNACE MUST BE INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS INCLUDED WITH THE CONTROL AND MUST BE MOUNTED WITHIN 6 OF THE BREACH OF THE FURNACE POWER SIDEWALL VENTING SEE SPECIAL INSTRUCTIONS IN INSTRUCTION MANUAL FURNACE LABEL SUMMERAIRE MFG PETE...

Page 2: ... connecting to burner The oil line should be buried and protected by cement to eliminate any possible damage Installations having the fuel oil tank below the burner level must employ a two pipe fuel supply system with an appropriate fuel oil pump Installation of the furnace Location Locate the furnace as closely as possible to the chimney providing ample clearance to permit easy accessibility for ...

Page 3: ...eed blower system enable partial air circulation at all times When the ther mostat calls for heat the burner starts and the high speed phase quickly distributes warmed air throughout the house When the high speed phase ceases the low speed phase continues circulating the air to even tem peratures throughout the dwelling High Limit Control The high limit control may be of a single switch type or co...

Page 4: ... 50 65 75 85 INPUT U S G H 65 75 85 1 00 INPUT B T U H 90610 104550 118490 139400 OUTPUT B T U H 75000 86000 96000 111000 NOZZLE PRESSURE psig 120 135 130 140 BURNER TURBULATOR SETTING 1 0 1 5 3 0 3 0 BURNER AIR SETTING 3 0 3 2 3 8 6 0 TEMP RISE F 85 85 85 85 EXT S P 20 20 20 20 C F M 785 890 1015 1220 MOTOR H P 1 3 1 3 1 3 1 3 MOTOR PULLEY 3 1 4 X 1 2 3 1 4 X 1 2 3 1 4 X 1 2 3 1 4 X 1 2 BLOWER PU...

Page 5: ......

Page 6: ......

Page 7: ... for use with Tjernlund SS1 C power side wall ventor When RME 111 is installed with SS1 C side wall ventor use 20 AMP circuit protection The Restrictor Plate supplied MUST be installed in the 6 portion of the Flue Pipe See detailed installation instructions below See SS1C Instruction Book for complete installation instructions 3 Feet 6 Tapered Reducer Appliance Restrictor Plate Cut slot to suit re...

Page 8: ...nd serv iced at least once a year by a licenced burner mechanic As part of this annual service ensure the flue pipe s are cleaned inspected and if required they should be replaced How to start your oil furnace The operation of the oil burner is entirely automatic To start it set the room thermostat above room tempera ture The oil burner will start automatically If the burner fails to start check t...

Reviews: