background image

Содержание GPG10360901A

Страница 1: ......

Страница 2: ...ind it if necessary Before using this manual check the serial plate for proper model identifica tion The installation and servicing of this equipment must be performed by qualified experienced technicians only GENERAL INFORMATION UNIT LOCATION This unit is approved only for an outdoor installation See the installa tion instructions for the required clearances to the unit It is important that safet...

Страница 3: ...D WHEN FUEL IS NOT BURNED COMPLETELYOR WHEN THE FLAME DOES NOT RECEIVE SUFFICIENT OXYGEN BE AWARE OF THESE AIR STARVATION SIGNALS WHICH INDICATE CONDITIONS THAT MAY RESULT IN CARBON MONOXIDE OR THAT CARBON MONOXIDE MAY BE PRESENT 1 HEADACHES NAUSEA DIZZINESS FLU LIKE SYMPTOMS 2 EXCESSIVE HUMIDITY HEAVILY FROSTED WINDOWS OR A MOIST CLAMMY FEELING IN THE HOME 3 SMOKE FROM A FIREPLACE WILL NOT DRAW U...

Страница 4: ... 7 immediately follow the instructions on the cover of this manual If you do not smell gas after five minutes move or rotate the gas control switch to the ON position The switch should turn easily Do not use excessive force 9 Reinstall the burner compartment door 10 Open the external manual gas shutoff valve 11 Turn on the electrical power to the unit 12 Adjust the thermostat to a setting above ro...

Страница 5: ...conditions TO PREVENT PERSONAL INJURY OR DEATH ALWAYS DISCONNECT THE ELECTRICAL POWER BEFORE INSPECTING OR SERVICING THE UNIT SlNCE ALL OF THE COMPRESSOR PROTECTION DEVICES RESET AUTOMATICALLY THE CONTACTOR AND OUTDOOR FAN MAY BE ENERGIZED WHEN RESET NOTE The operation of the indoor blower will not be affected by any compressor protection devices If during a call for cooling the indoor fan runs an...

Страница 6: ...r unit A dirty filter is the most common cause of inadequate heating or cooling performance Filter inspection should be made at least every two months more often if necessary because of local conditions and usage Dirty throw away filters should be discarded and replaced with a new clean filter Dirty permanent filters should be washed with water thor oughly dried and sprayed with a filter adhesive ...

Страница 7: ... should not be operated in enclosed areas such as unventilated garages utility rooms or parking areas because of the danger of carbon monoxide CO poisoning resulting from the exhaust emissions If a furnace or air handler is installed in an enclosed area such as a garage utility room or parking area and a carbon monoxide producing device is operated therein there must be adequate direct outside ven...

Страница 8: ...Safety Labels 2003 Goodman Manufacturing Company L P 8 ...

Отзывы: