Procedure
1. Remove the protective plug.
2. Put the sensor (A) in position on the
manifold (B).
3. Manually turn the sensor clockwise
until the flange (C) on the sensor
touches the manifold.
4. Tighten the sensor with a torque
wrench.
Torque the sensor to 50 ± 5 Nm.
Caution: Do not tighten
the sensor too much. This
can cause damage to the
manifold.
Install the water saturation - oil temperature sensor
Caution: Install the sensor correctly in the manifold. If you install the sensor
incorrectly, the device does not operate correctly or it shows incorrect
measurements.
Note:
• For an overview of the connections, refer to section
on page 11.
• To connect the sensor to a LM2 Gears CMS, refer to the user manual of
the LM2 Gears CMS.
Procedure
1. Remove the protective plug.
2. Put the sensor (A) in position on the
manifold (B).
3. Manually turn the sensor clockwise
until the flange (C) on the sensor
touches the manifold.
4. Tighten the sensor with a torque
wrench.
Torque the sensor to 45 ± 4.5 Nm.
Caution: Do not tighten
the sensor too much. This
can cause damage to the
manifold.
A
C
B
6.3.6
A
C
B
Installation
UM_VP2500L_002_EN
23