Page 26 of 47
CODE
EVENT
WHAT
TO
DO
A001
Charger is not suitable or
damaged, the battery is
in protection mode.
The battery should be checked and restored at the
service center Suex.
A002
The battery has been
discharged with an
excessive current.
Switch off the scooter by main switch and wait
minimum 5 seconds. Switch on the scooter by the
main switch.
After 5 events the display of the battery is StoP. The
scooter works in any case but you must contact suex
assistance.
A003
Overheating power
stage.
Automatic reset to the cooling of the battery pack.
A004
Overvoltage.
At least one cell has exceeded the maximum
allowable voltage, the system self-resets lowering of
the voltage.
A005
Short circuit during the
charging phase.
The battery must be checked and reset at a service
center Suex, must also be checked charger used.
A006
Short circuit in the
discharge phase.
Switch off the scooter by main switch and wait
minimum 5 seconds. Switch on the scooter by the
main switch.
After 5 events the display of the battery is StoP. The
scooter works in any case but you must contact suex
assistance.
A007
Cut-off for battery too
low.
The system self-resets the subsequent charging of
the battery
A008
Error BMS.
Probable failure of the BMS must be replaced
exclusively by Suex.
A009
Overheating control
logic.
Automatic reset to the cooling of the battery pack.
A010
Battery no longer usable.
Excessive discharge of the cells, battery out of
use, service only exclusively Suex.
Aoff
After 4 hours of scooter inactivity stored with the main
switch on, the system switch off the scooter to avoid
the discharge of the battery. Turn the main switch off,
wait 5 second or more and switch on the scooter.
StoP
See A002 and A006.