38
Appendix
!
WARNING
Take the dive computer to an authorised SUBGEAR dealer in order to change the batteries. The
battery replacement is carried out by a SUBGEAR subsidiary. XP AIR is checked for its technical
integrity at the same time. Do not attempt to have the batteries changed by anyone other than
an authorised SUBGEAR dealer.
2.1 Replacing the battery of the transmitter
!
WARNING
It is recommended to have the battery of the transmitter replaced by an authorized SUBGEAR
dealer. The change must be made with particular care in order to prevent water from seeping in.
The warranty does not cover damages due to an improper replacement of the battery.
Transmitter battery set
(PN 06.201.920):
Includes a Type CR 2450 battery and a 26.00 x 2.00 mm transmitter
cap o-ring.
!
WARNING
Never touch the metal surface of the battery with bare fingers.
The two battery poles must never be short circuited.
HP port o-ring
8.73 x 1.78 mm
Transmitter screws
PT
®
KA 30 x 16 mm
Transmitter cap o-ring
26.00 x 2.00 mm
Transmitter Battery
CR2450
Transmitter Cap
Procedure:
To replace the battery you need a Phillips screwdriver and a clean cloth.
!
WARNING
• A leaking transmitter cap may lead to the destruction of the transmitter by water seeping in
or cause the transmitter to switch off without prior notice.
• Always open the transmitter in a dry and clean environment.
• Only open the transmitter to replace the battery.
1. Remove the transmitter from the HP outlet of the first stage of the regulator.
2. Dry the transmitter with a soft towel.
3. Remove the 3 screws with the Phillips screwdriver.
4. Remove the transmitter cap carefully.