Introduction

Get to Know Your Controller

LED Indication.

4

7

Parameter List.

Key Introduction

5

3

Fault Messages.

6

DESCRIPTION

PARAMETER

Pg. 
No.

To set the cut-out point of the controller.

SET POINT

8

DESCRIPTION

PARAMETER

Pg. 
No.

Items Included.

4

8

To set other parameter

8

To set allowable high temperature limit. 

To set allowable low temperature limit.

To set the differential for compressor 
restart. 

P2 

P3

P4

9

9

10

To set  probe calibration.

P5

10

To set time delay between relay restart 
time.

P6

10-11

To set duration of defrost.

P7

11

To set defrost frequency.

To set power on defrost delay.

P8

P9

11

11

To enable / disable buzzer.

BUZ

12

This parameter is used to set power on 
delay for alarm.

AL

12

Under load limit for compressor current.

C-UL

12

Over load limit for compressor current.

C-OL

13

Current sensing delay.

C2

13

To enable or Disable HP sensing. 

D0

13

To enable or disable LP sensing.

D1

14

Fault sensing logic.

D2

14

To set LP sensing delay.

To set  reset mode for HP fault.

D3

D4

14

15

15

To set Compressor Relay status on 
Probe Failure.

To set On cycle at room probe fail.

To set Off cycle at room probe fail.

To set Display at defrosting.

E1

TON

TOFF

E7

16

16

16

16

To set time delay to switch off the light .

To change password.

To view Compressor run Hours.

Clear Compressor Run Hours.

To set Unit ID. 

LD

PW

CRH

CCRH

Unit ID

17

17

17

17

18

To activate Keypad Lock.

To enable/disable Power Switch. 

To set display at power OFF mode.

LP

PO

PDIS

18

18-19

19

To restore default settings of the 
controller.

FS

19

End of programming.

EP

19

Technical Data

20

Caution & Warranty

21

30-31

Suggested Wiring Diagram

DI-D

OPS

To select AUX or compressor thermal 
trip digital I/P
To Enable / Disable Oil Pressure Switch 
(OPS) I/P.

15

21-28

Instruction manual for VMRC-10/3

CRC-2020

CRC-2020

29

Summary of Contents for CRC-2020

Page 1: ...AMP CRC 2020...

Page 2: ...ssor current C OL 13 Current sensing delay C2 13 To enable or Disable HP sensing D0 13 To enable or disable LP sensing D1 14 Fault sensing logic D2 14 To set LPsensing delay To set reset mode for HPfa...

Page 3: ...t up the instrument for each specific function The CRC 2020 controller can be used for several applications with a measuring range from O O 50 0 C to 50 0 C Computer Connectivity over RS485 and Remote...

Page 4: ...croll in Program mode Used to enter into the program mode Used to switch OFF ON the light Used to enter into the Amp mode where compressor current can be viewed AMP High temperature alarm for Room mea...

Page 5: ...that the set point has been stored in memory 01 To change Set Point parameter press the set key P3 0 5 C P2 0 5 C 0 0 C Range Min Max Fact Set To set other parameter Press hold PRG key for 2 seconds D...

Page 6: ...the set point 0 is set at 10 0 C and differential is set at 0 2 0 C then when the system reaches 0 10 0 C the comp relay will cutout Since 0 the differential is 2 0 C the comp Relay 0 will cutin at 1...

Page 7: ...ill take place once Example If P9 parameter is 30 mins then at power after 30 mins defrosting will take place once BUZ Parameter 09 Function To enable disable buzzer To change the BUZ Parameter parame...

Page 8: ...ault for compressor If this parameter is set to Enable then controller will detect HP trip To change the D0 parameter press the set key D0 Parameter 14 Function To enable or Disable HP sensing DIS ENB...

Page 9: ...emperature will be dispalyed DEFR At Defrosting Defrost ON will scroll 24 Function To set Display at defrosting To change E7 parameter press the SET key TEMP DEFR TEMP Range Min Max Fact Set Range Min...

Page 10: ...ed to set the Unit ID of the device 29 Function To set Unit ID To change Unit ID parameter press the SET key 1 240 Range Min Max Fact Set Range Min Max Fact Set NO YES NO CCRH 28 Function Clear Compre...

Page 11: ...normal mode and displays the Room Temperature and all settings are recorded 34 Function To exit programming To exit programming parameter press the SET key 20 CRC 2020 Technical Data Housing Plastic...

Page 12: ...To set Reference Voltage 23 23 DESCRIPTION PARAMETER Pg No To set program mode 23 To set Undervoltage Limits 25 To set Un Balance Value To set Time Delay 25 To set Calibration of Voltage To set Calib...

Page 13: ...ce value To change the unb parameter press the set key 10V 120V 60V Range Min Max Fact Set Use UP DOWN keys to set desired value If the a c voltages goes below this limit will trip respective a c on u...

Page 14: ...t desired value There are two type of display output Line to Line Voltage L L and Line to Neutral L n Depending on this parameter REF parameter also changes 26 Sr No Parameter setting method Descripti...

Page 15: ...1 2 RELAY NC C NO 3 7 8 9 R 15 17 19 18 21 Y B N Main Functions Voltage Monitoring Phase Sequence Monitoring Phase Loss and Phase Unbalance detection Uv and Ov Detection Settable Uv and Ov Parameter...

Page 16: ...29...

Page 17: ...mages No part of this manual may be reproduced or transmitted in any form or by any means without the prior written permission of the company Notice Disclaimer Warranty This manual its contents remain...

Page 18: ...Globe Valves Hand Valves Flow Switches Solenoid Valves OUR OTHER PRODUCTS Cold Room Controller Chiller Controller Two Compressors Controller Heating Controller Humidity Controller Pressure Controller...

Reviews: