Integrated
Integrated
(700-
(700-
3
3
T
T
ALL)
ALL)
Series
Series
Component Access/Removal
7-21
#3758412 - Revision B - December, 2006
High-Side Filter-Drier Removal
The high-side filter-driers are located in the center of
the unit tray, behind the condenser and are attached to
the drier bracket with a cable tie.
NOTE:
Before attempting to remove a filter drier, evac-
uate the refrigerant from the sealed system.
To access and remove a high-side filter-drier, the kick-
plate/grille will need to be removed first and the unit
tray will need to be slid out. To slide the unit tray out,
extract the two screws that secure the tray to the unit,
located at the front right and left corners. Grab the front
flange of the tray and pull forward. (See Figure 7-46)
NOTE:
It may be necessary to disconnect the com-
pressor electrical leads in order to pull the tray out far
enough to access the filter-driers.
1.
Remove a filter-drier by cutting the cable tie which
secures filter-driers to the bracket. (See Figure 7-
47)
2. With file edge, score a line around capillary tube
approximately one inch from filter-drier outlet, then
fatigue capillary tube at this line until it separates.
3. With a tube cutter, cut the inlet tube approximately
one inch from filter-drier.
NOTE:
Sweating the joints apart is not recommended
as this may induce moisture into the sealed system and
could cause a solder restriction in the capillary tube.
NOTE:
Check the end of the remaining capillary tube
for internal burrs. If burrs exist, re-score a line around
the capillary tube (approximately one inch from the end)
and fatigue the capillary tube at this new line until it
separates.
NOTE:
When installing the replacement filter-drier,
insert the capillary tube until it touches the screen, then
pull the capillary tube approximately 3/8” away from the
screen before brazing. (See Figure 7-48) When
installing a new filter-drier, be sure to thoroughly clean
the tubing before brazing.
Figure 7-46. Sliding Unit Tray Out
Screw
Screw
Figure 7-47. Filter-Drier Removal
3/8"
Figure 7-48. Filter-Drier Cut-Away View
Cut cable tie
Score a line 1” from drier
Cut 1” from drier
Capillary Tube
Screen inside
Filter-Drier
Summary of Contents for 700TC-3
Page 2: ......