Troubleshooting Guides
8-19
#3758412 - Revision B - December, 2006
PROBLEM
POSSIBLE CAUSE
TEST / ACTION
X. Lights Stay ON when Door
&/or Drawers are Closed -
(May be Accompanied by
Door/Drawer Ajar Alarm Bell)
Y. Door or Drawers Not Able to
Close Completely
Z. Door or Drawers Uneven
Door or Drawer Ajar
a. Food product obstruction
b. Door/cabinet hinge problem
c. Drawer closer tripped backwards
Top Hinge Cover Missing
Light Switch Defective
Wiring to Light Switch and Fan Switch
Crossed
Food Product Obstruction
Door/Cabinet Hinge Problem
Drawer Closer Tripped Backwards
Improper Door or Drawer Panel
Installation
Unit Not Level
a. Move obstruction.
b. See hinge adjustment procedures at end of
troubleshooting guides. Replace hinge if
defective.
c. Trip drawer closer forward
Install hinge cover
Check for 115V AC to and from light switch.
Replace switch if defective.
Check operation of light switch and fan
switch, lights OFF when light switch
depressed, fan ON when fan switch
depressed. If crossed, reconnect wiring
correctly.
Move obstruction.
See Door Hinge Operation Test Procedures
later in this section. Replace hinge if defec-
tive.
Trip drawer closer forward
The doors and drawers are non-adjustable.
Instead, the door and/or drawer panels must
be adjusted if there is an alignment prob-
lem. Refer to the Installation Manual and/or
installation video for panel installation and
adjustment.
Check levelness of unit. If un-level, turn
front leveling legs counterclockwise to raise
front or clockwise to lower it. Rear levelers
are adjusted from front of base by turning
adjusting screw clockwise to raise rear or
counterclockwise to lower it. Refer to the
Installation Manual and/or installation video
for complete installation and leveling instruc-
tions.