Page 27
Bar Code - Angle Min*
Command = 25, Data Bytes = 5
Note: Angle Min represents Timer Min in the TCV-
Ethernet. The Timer Max is 2.55 seconds, pro-
grammed as 255, and the Timer Min must be less
than the Timer Max.
Bar Code - Angle Max*
Command = 25, Data Bytes = 5
Note: Angle Max represents Timer Max in the
TCV-Ethernet. The Timer Max is 2.55 seconds,
programmed as 255, and the Timer Max must be
greater than the Timer Min.
Bar Code - Angle Final Target
Command = 27, Data Bytes = 5
Bar Code - Job Sequence Number
Command = 42, Data Bytes = 5
Bar Code - Parameter Set Name
Command = 47, Data Bytes = 1 - 25
Bar Code - Batch Reset
Command = 10, Data Bytes = 0
*%25%00010%*
*%26%00255%*
*%27%00100%*
*%42%12345%*
*%47%PARAMETER-A%*
*%10%%*