![background image](http://html1.mh-extra.com/html/stuart/ph35/ph35_installation-operation-and-maintenance-instructions-manual_1386300005.webp)
- 5 -
Cont ...
5 TECHNICAL
SPECIFICATION
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
*Note: Max working pressure is the maximum pressure that can be applied to
the pump internal casing under any installation conditions.
**Note: In normal circumstances the temperature of stored water should never
exceed 65 °C. A stored water temperature of 60°C is considered
sufficient to meet all normal requirements and will minimise deposition of
scale in hard water areas.
5.11
Noise:
The equivalent continuous A-weighted sound pressure level at a distance
of 1 metre from the pump does not exceed 70 dB(A).
Model
PH35
PH45
Electrical
Power supply
Volts/phase frequency
230/1/50
230/1/50
Enclosure
IPX4
IPX4
Type of motor
Induction
Induction
Power consumption
380Watts
540 Watts
Full load current
1.6 Amps
2.4 Amps
Rating
Continuous (S1)
Continuous (S1)
Max. No Starts per hour
60
60
Mechanical
Min inlet head
1 metres
1 metres
Max inlet head
10 metres
10 metres
Max head (closed valve)
25 metres
42 metres
Max working pressure*
600 kPa (6.0 bar)
900 kPa (9.0 bar)
Max ambient air temperature
50
o
C
50
o
C
Max water temperature**
80
o
C
80
o
C
Min water temperature
4
o
C
4
o
C
Cut in flow
1 l/min (approx)
1 l/min (approx)
P
ump
Dimensions
Length (max)
241 mm
270 mm
Width (max)
130 mm
130 mm
Height (excluding flexible hoses)
167 mm
167 mm
Gross Weight (including accessories)
4.9 Kg
6.5 Kg
Pump Connections: Inlet
G 1 Female
G 1 Female
Outlet
G 1 Female
G 1 Female
Materials
Body
Brass
Brass
Shaft
Stainless Steel
Stainless Steel
Mechanical Seal
Nitrile/carbon/ceramic
Nitrile/carbon/ceramic
Summary of Contents for PH35