background image

- 2 -

PRODUCT DESCRIPTION

Electric motor driven single stage end suction centrifugal pump.

APPLICATION

The range of centrifugal pumps is designed to pump clean fresh water.  Other clean, non 
aggressive, non explosive liquids with similar characteristics to water may be pumped.  
Consult Stuart Turner for advice on such applications.
The pumps can be used for pressure boosting, fluid transfer and distribution.  They are 
suitable for flooded suction applications.  Alternatively a maximum suction lift of    
4.6 metres is permitted when using a Stuart footvalve/strainer.

Inlet pressures to the pump and ambient temperatures must not exceed the values 
given in the technical specifications.

 

This pump set must not be used for any other application without the    

 

written consent of Stuart Turner Limited.

 

This pump must not be connected directly to the mains water supply.

 

This product should not be used for the supply of water to more than    

 

one dwelling (house, apartment, flat).

Please read installation details carefully as they are intended to ensure this product 
provides long, trouble free service.  Failure to install the unit in accordance with the 
installation instructions will lead to invalidation of the warranty.

STORAGE

If this product is not to be installed immediately on receipt, ensure that it is stored in a dry, 
frost and vibration free location in its original packaging.

CONTENTS 

Page

Checklist  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Commissioning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Technical Specifi cation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

CHECKLIST

Your product may vary slightly from the picture above.

Item Description

Qty Item Description

Qty

Pump

1

A

A

Fig. 1

G 1 Outlet

Priming
Plug

G 1 Inlet

IMPORTANT:  With the pump 
removed from its packaging 
check for any damage prior to 
installation.  If any damage is 
found contact Stuart Turner Ltd 
within 24 hours of receipt.

Summary of Contents for PH35

Page 1: ...his instruction booklet with the owner as it contains important guarantee maintenance and safety information Read this manual carefully before commencing installation This manual covers the following products CE compliant product PH35 Pt No 46563 PH45 Pt No 46564 ...

Page 2: ...cted directly to the mains water supply This product should not be used for the supply of water to more than one dwelling house apartment flat Please read installation details carefully as they are intended to ensure this product provides long trouble free service Failure to install the unit in accordance with the installation instructions will lead to invalidation of the warranty STORAGE If this ...

Page 3: ...r devices which contain non return valves in the suction inlet pipework to the pump The pump must be free to vent to the supply tank at all times 1 13 DO NOT run against a closed valve for periods longer than 5 minutes 1 14 DO NOT allow the supply cord to contact hot surfaces including the motor shell pump body or pipework The cod should be safely routed and secured by cable clips 1 15 Protection ...

Page 4: ...lves and vent prime pump head a Loosen priming plug and allow an even flow of water this may take a few seconds b Re seal draining plug nipping tight The pump is now ready to start 4 MAINTENANCE 4 11 No routine maintenance is required but provision should be made for easy access to the pump to allow for repairs due to normal wear and tear Isolate the pump from the electricity supply turn off liqui...

Page 5: ...se frequency 230 1 50 230 1 50 Enclosure IPX4 IPX4 Type of motor Induction Induction Power consumption 380Watts 540 Watts Full load current 1 6 Amps 2 4 Amps Rating Continuous S1 Continuous S1 Max No Starts per hour 60 60 Mechanical Min inlet head 1 metres 1 metres Max inlet head 10 metres 10 metres Max head closed valve 25 metres 42 metres Max working pressure 600 kPa 6 0 bar 900 kPa 9 0 bar Max ...

Page 6: ...ation improper use unauthorised repair normal wear and tear and defects which have a negligible effect on the value or operation of the pump Reasonable evidence must be supplied that the pump has been purchased within the applicable guarantee period prior to the date of claim such as proof of purchase or the pump serial number In the event of a claim please telephone Stuart Turner Limited on 0844 ...

Page 7: ... 7 NOTES ...

Page 8: ...08 EC BS EN 55014 1 BS EN 55014 2 BS EN 55022 BS EN 61000 3 2 BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 11 1999 519 EC BS EN 62233 2011 65 EU IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP AS SERIAL NUMBER BELOW COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E E C DIRECTIVES RESPONSIBLE PERSON AND MANUFAC...

Reviews: