Stuart Turner reserve the right to amend the specification in line with its policy of 

continuous development of its products.

 

*Note:  The maximum pressure that can be applied to the pump under any    

 

 

installation conditions.

 

**Note: With footvalve fitted.

5.11 

Noise:  

The equivalent continuous A-weighted sound pressure level at a  

 

 

distance of 1 metre from the pump does not exceed 70 dB(A).

5  TECHNICAL SPECIFICATION

Pump Model

PH 35 ES

50 Hz

46563

PH 35 ES

50 Hz

46451

PH 45 ES

50 Hz

46564

PH 45 ES

50 Hz

46454

General

Guarantee

2 years

WRAS approval

Approved materials

Approvals

CE

Features

Pump type

Peripheral

Priming vent plug

ü

ü

ü

ü

Typical noise

61 dB(A)

64 dB(A)

Materials

Pump body

Brass

Impeller

Brass

Mechanical seal

EPDM / PTFE /

Al. Oxide

Viton / Carbon / 

Silicon Carbide

EPDM / PTFE /

Al. Oxide

Viton / Carbon / 

Silicon Carbide

Performance Maximum head - closed valve

3.0 bar / 30 metres

4.2 bar / 42 metres

Performance @ 9 l/min

2.0 bar / 20 metres

3.2 bar / 32 metres

Performance @ 18 l/min

1.2 bar / 12 metres

2.3 bar / 23 metres

Maximum flow

32 l/min

40 l/min

Minimum static inlet pressure

0.05 bar (0.5 metres)

Maximum static inlet pressure

1.4 bar (14 metres)

Maximum working pressure*

600 kPa (6 bar)

Maximum viscosity

50 secs redwood no. 1 9.5 centistokes

Max. ambient air temperature (continuous)

40 

o

C

40 

o

C

40 

o

C

40 

o

C

Max. ambient air temperature (intermittent)

50 

o

C

n/a

50 

o

C

n/a

Min / Max water temperature

Min 4 

o

C / Max 80 

o

C

Maximum suction lift**

4.6 metres

Connections

Pump connections

G 1 female

Motor

Type

Induction, auto-reset thermal trip

Duty rating

Continuous (S1) @ 5 l/min and above

Electrical

Power supply (Vac/Ph/Hz)

230 V a.c. / 1 / 50 Hz

Power consumption - P1

450 Watts

665 Watts

Current - full load

1.95 Amps

2.9 Amps

Fuse rating

5 Amps

Power cable length

1.5 metres (pre-wired)

Physical

Enclosure protection

IP44

Length

241 mm

257 mm

Width

132 mm

Height - excluding hoses

169 mm

Weight - including fittings

4.6 Kg

6.2 Kg

Summary of Contents for PH 45 TS S

Page 1: ...Read this manual carefully before commencing installation This manual covers the following products suitable for 230 1 50 supply PH 35 TS Pt No 46496 PH 35 TS Pt No 46445 PH 45 TS Pt No 46504 PH 45 T...

Page 2: ...ambient temperatures must not exceed the values given in the technical specifications STORAGE If this product is not to be installed immediately on receipt ensure that it is stored in a dry frost and...

Page 3: ...d closed valve PH 35 TS 30 metres PH 45 TS 42 metres PH 35 ES 30 metres PH 45 ES 42 metres z z The motor casing can become very hot under normal operating conditions Care must be taken to ensure it ca...

Page 4: ...rnal wiring all cable routing and securing details are carefully noted to ensure re assembly to the same factory pattern is always maintained z z If the supply cord is to be changed or is damaged it m...

Page 5: ...ay vary slightly from the picture above Fig 1 IMPORTANT With the pump removed from its packaging check for any damage prior to installation If any damage is found contact Stuart Turner Ltd within 24 h...

Page 6: ...on where the maximum ambient temperature should not exceed 40 o C continuous or 50 o C intermittent ES models only 1 16 DO NOT fit a pump if the hot water is heated via a method whereby the water temp...

Page 7: ...ation 2 15 Water retention Site the pump in a location where in the unlikely event of a water leak any spillage is contained or routed to avoid electrics or areas sensitive to water damage 2 16 Pump p...

Page 8: ...be permanently connected to the fixed wiring of the mains supply using the factory fitted supply cord via a dedicated double pole switched fused spur off the ring main 3 17 Wiring of connection unit W...

Page 9: ...arefully noted to ensure re assembly to the same factory pattern is always maintained 3 21 If the supply cord is to be changed or damaged it must be replaced by a special cord available from Stuart Tu...

Page 10: ...ves in the closed position Damage will occur The pump must be primed filled with water before starting 4 16 Flooded suction conditions Turn on the isolating valves a Loosen vent plug and allow an even...

Page 11: ...metres Maximum flow 34 l min 44 l min Minimum static inlet pressure 0 05 bar 0 5 metres Maximum static inlet pressure 1 4 bar 14 metres Maximum working pressure 600 kPa 6 bar Maximum viscosity 50 sec...

Page 12: ...e 3 0 bar 30 metres 4 2 bar 42 metres Performance 9 l min 2 0 bar 20 metres 3 2 bar 32 metres Performance 18 l min 1 2 bar 12 metres 2 3 bar 23 metres Maximum flow 32 l min 40 l min Minimum static inl...

Page 13: ...ut no liquid Air locked Bleed pipework and pump to clear air No liquid supply Check the supply valves are turned on Check outlet not restricted or blocked Connections reversed Check liquid connections...

Page 14: ...e value or operation of the pump Reasonable evidence must be supplied that the product has been purchased within the guarantee term prior to the date of claim such as proof of purchase or the pump ser...

Page 15: ...15 NOTES...

Page 16: ...00 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 11 EMF Directive 1999 519 EC BS EN 62233 RoHs Directive 2011 65 EU WEEE Directive 2012 19 EU IT IS...

Reviews: