Varan 1.14, 1.20
Changes in models reserved.
Dimensions not binding!
20
Controller
6.2 Aufrufen des Menüs
Hold button P3 (SET) to open the menu. Use the arrow keys to select a menu item and confirm the choice with P3 (SET).
Menu item
Description
Combustion Power
Modification of the combustion programmes: AUTO, P1, P2 oder P3
Heating Power
Not used.
Boiler Thermostat
Set the desired boiler temperature.
Buffer Thermostat
Set the desired buffer or domestic hot water tank temperature.
Not visible if P26 = 2, 3 or 4.
Room Thermostat
Set the desired room temperature (if a room sensor is present).
Only visible if A19 = 1.
Chrono Modality
Select programme: Day, week, weekend, deactivated
Chrono Program
Adjust 3 switching cycles per day.
Time and Date
Set time and date.
Remote Control
Not used.
Calibration
Set auger run time and fan RPM
Load
Select this menu item to transport a starting load of pellets into the combustion
chamber (after pellet tank has been emtied completely. After selection, the auger
will run continously until a manual stop.
Summer-Winter
Select between winter or summer mode.
Summer mode only provides domestic hot water.
Language
Select the language shown on the controller menu.
Keyboard Menu
Set contrast and min. backlighting.
System Menu
Allows settings reserved for qualified personnel.
6.3 Menu Use
- To activate the menu, press P3 (SET).
- The display will show a list of menu items. Use the buttons
P4 (^) and P6 (v) and select – for example – ‚Combustion
Power‘.
- Confirm the selection with P3 (SET). It is now possible to
change the setting..
- The now visible screen (see scheme on the right side)
allows to change the setting using the buttons P4 (^) and
P6 (v); switching between Auto, 1, 2, 3.
- Confirm and safe your selection with P3 (SET).
- To return to the main screen, press P1 (ESC).
- If the controller did not successfully apply the new setting, the
display will read ‚Transmission not successful‘.
In this case, repeat the previous steps.
Parameter
Current setting