Installation
Situation 2:
- In this situation flue pipe must go at least 1.5 meters
vertically upwards in the very room where the boiler is
placed. Penetrate through the wall and connect the pipe
onto the chimney.
- The flue pipe must have a T-piece for condensation at the
outlet of the boiler and the possibility of dismantling for
cleaning.
WARNING
: Failure to follow the rules during the execution
of flue and chimney can lead to malfunction of the boiler and
danger to objects and to human health. The most notable danger
is from the toxic gases (carbon monoxide) which are the products
combustion process.
Important: We recommend to perform a chimney evaluation
prior to installation.
1
Condensate collector
2
T-piece
3
Flue pipe
4
Knee 90° female-male fittings
5
Rosetta female-female fittings
6
Rosetta male-female fittings
7
Knie 90° male-male fittings
8
Wall brackets
9
Cover
Outdoor parts must
be insulated