Operation and control
V 152 10 11
Rev.: END
5-13
5.5
Faults in operational sequence
Pressing shield does not move when in standard cycle
Causes:
–
Door or loading flap not closed
–
Door temporarily opened
–
Pressing shield is not in the upper end position
Rectification
Close the press chamber door or the loading door.
Move the pressing shield up in manual mode. Restart the cycle
by pressing START.
Red "FAULT" signal lamp is flashing
Causes:
–
Loading door not closed
Rectification
Close the loading door.
Set the solenoid – sensor distance on the loading door.
Pressing shield does not move up again when in automatic mode:
Causes:
–
Emergency Stop pressed
–
Press chamber/loading flap temporarily opened
–
Power failure
–
Bales finished message on (foil programme option)
–
Power supply interrupted
Rectification
Release the Emergency Stop button. Move the pressing shield up
in manual mode.
Close the press chamber/loading door. Move the pressing shield
all the way up in manual mode.
See Bale finished (Chapter 5.4.3).
Move the pressing shield all the way up in manual mode once the
power is resumed.
Summary of Contents for Plus 70
Page 58: ...Appendix V 152 10 11 Rev END 8 2 8 1 Declaration of Conformity...
Page 59: ...Appendix V 152 10 11 Rev END 8 3 8 2 Assembly drawings...
Page 60: ...Appendix V 152 10 11 Rev END 8 4 8 3 Parts list with recommended identified spare parts...
Page 61: ...Appendix V 152 10 11 Rev END 8 5 8 4 Hydraulic diagram parts list...
Page 62: ...Appendix V 152 10 11 Rev END 8 6 8 5 Circuit diagram parts list...
Page 63: ...Appendix V 152 10 11 Rev END 8 7 8 6 Supplier documentation...