Site Preparation Guide
Site Prep Tasks
Page 9
Electrical Requirements
AC Power Requirements
• 50/60 Hz
• Voltage: 100-132 VAC
• Current: 15/7A
• The V650 Flex uses standard 120V, 15A power input. The power cord is coiled inside the
computer bay (
), allowing a qualified electrician to connect the printer to a facility
power source.
• The grounded electrical outlet must connect to a US power cord plug (provided by
customer) and must be located within 2 m (80 inches) of the printer.
Operation of the printer outside this range is not recommended; degradation of performance
and shortened component life expectancy will be experienced. Facilities who are unsure of
their power quality should contact their service provider.
Figure 7: V650 Power Cord Location
Caution:
Do not use an extension cord or power strip; doing so can result in intermittent power
issues. Connect the power cord directly into the receptacle or UPS.
Power Cord