LED Indicators
These indicators show the control box input/output status. (Fig. 13)
1. LS1:Timing
The LS1 counts holes in the timing plate. The LED lights each time the LS1
reads a hole.
2. LS2:Confirm zero position
The LS2 confirms the zero position.
The LED lights each time the LS2 reads a hole.
3. LS3:End of strapping material detected
The sensor detects the end of the coil of strapping material.
The LED lights when this sensor is activated.
4. LS4:Pool
The sensor detects that strapping material in the pool is almost the end.
The LED lights when this sensor is activated.
5. LS5:Reverse pulse
Lights with each count.
6. Spare
7. HEATER:Heater
The LED lights when the heater is supplied
with power.
8. M1:Sealing motor
Lights while this motor is turning.
9. M2:Pool motor
Lights while this motor is turning.
10. BR1:Sealing brake
Lights while the power is applied to the brake.
11. CL1:Sealing clutch
Lights while the power is applied to the clutch.
12. CL2:Secondary Tensioning clutch
Lights while the power is applied during the
secondary tensioning.
13. SOL1:Reverse solenoid
Lights while charged.
14. SOL2:Secondary tightening solenoid
Lights while it is operating.
15. SOL3:Forward solenoid
This LED goes out while in forward rotation.
16. SOL4:Spare
17. SFM:Smoke fan
Lights while it is turning.
18. START:Start
Lights while this button is pressed.
19. ERROR:Overload
Indicates that a motor is overloaded. Shows steady red light when the M1 motor
is overloaded. Shows a blinking red light when the M2 motor is overloaded.
20. A-LIMIT:Current limit, pool error
M1 motor overcurrent;Steady red light.
M2 motor pool error;Blinking red light.
Fig. 13