1
No Power at outlet.
1
Check power source.
2
Fuse blown or dislodged.
2
Check Fuse. (P. 15)
Lamp Flashes
3
Quick Warm Heater circuit is activating.
3
Wait for
25 see., and press Start Switch. (P. 7)
4
Energy Saving Circuit is activating.
4
Press Start Switch once.
(P. 7)
5
Motor overload.
5
Press Reset Switch.of Rear Operation Panel.
6
Stop Switch is locked.
6
Release the Stop Switch. (P. 7)
7
Poor connection at or within Start or Stop Switch.
7
Secure the
connection or replace the Switch.
8
Improper threading of strap.
8
Re-shread the strap. (P. 9)
9
Insufficient or excessive strap in Pool Box.
9
Re-adjust the amo
unt of strap poold. (P. 11)
10
Strap dust in Feed Unit.
10
Clean. (Fig. 14)
11
Tip of strap is cracked.
11
Adjust or replace Cutter Upper/Lowe
r.
12
Strap jumps out from flaps.
12
Replace broken Arch Flap Spring.
13
Poor quality of strap.
13
Cut off the poor parts of strap,
or change strap coil.
14
Improper Home Position.
14
Readjustment of Timing Plate. (P. 1
2)
15
Short T2 timer setting.
15
Readjust the Feed timer. (P. 15)
16
Insufficient Feed pressure.
16
Readjust the Feed pressure. (P.
13)
Insufficient Reverse pressure.
Readjust the Reverse pressure.
17
Stopper bolt is too long to transfer the reversing
17
Readjustm
ent of Stopper Bolt.
pressure.
18
strap is folded and jammed.
18
Remove Band Guide Plate and Feed
Band Guide Plate to remove jammed
strap.
19
Heater wiring is damaged, Heater defective or
19
Replace Heater
Blade, or clean
loos/disconnected at terminal.
the blade when PP dregs are on
the blade.
20
Improper Heater temperature.
20
Readjust the heater temperature
.
21
Strap does not reach at slide table.
21
Readjust the Home Posit
ion. (P. 12)
22
Heater Plate does not to be positioned between
22
Replace Heate
r Tension Spring or re-position the Heater.
straps.
23
Excessive tension for a package.
23
Readjust Tension Dial. Or,
re-adjust VR2 volume. (P. 15)
24
T1 Timer is short for its setting.
24
Readjust T1 timer. (P. 1
5)
25
Defective T3 timer.
25
Replace T3 timer. (P. 7)
26
Improper positioning of package.
26
Re-position package.
Lamp lights.
Problem
Causes
Corrective Actions
Lamp does not
light.
Start Button
pressed.
Machine does
not work.
PILOT LAMP;
Start Button
Pressed.
Machine Works, but
Irregular
forwarding/
reversing of
strap.
Strap
unsealed.
Improper
Tensioning
-17-