Malkeanlæg/Melkanlagen/Milking systems
8560930b
230299
TK
Brugervejledning/Bedienungsanleitung/Users’ manual
67
Symptom
Possible
error
Rectified
B.
Wrong Vacuum
k.
Leakage in the releaser /
milk pump.
- Please see section A.
l.
Leakage in the moisture trap.
- Please see section A.
m.
Wash switches / 3-Way Cock
in the wrong position.
- Check the position.
Symptom
Possible
error
Rectify
C.
Too Little Pump Capacity
a.
Pump segments are stuck
due to:
- dirt.
- wrong oil type.
- wrong oil consumption.
- clean the pump and
lubricate it.
- clean the pump and
change to the right type
of oil.
- Clean the pump - see
previous or section 2.1.
b.
Wrong tightness of belt.
- Adjust the belt tightness -
see section A.
c.
No vacuum on the oil stub.
- Clean the vacuum pump
as described in section
2.1. - if it does not help,
please call a service
fitter.
d.
Defective seatings or pump
segments.
- Send the pump for repair.