INSTALLATION
Make sure that the flexible
connector does not block the cooling
fan inlet.
4. Flexible connections should comply
with BS 669.
Parts of the appliance likely to come into
contact with a flexible connector have a
temperature rise of less than 70°C.
5. Rigid connections must be accessible
to disconnect for servicing.
Cut a 150mm square hole in the right
hand rear corner of the support shelf for
the supply pipe.
6. Make sure all connections are gas
sound.
Step 3 : Connect to the electricity
supply
Warning: This appliance must be
earthed.
For products fitted with a plug
The flexible mains lead is supplied con
-
nected to a BS 1363 fused plug, the plug
is fitted with the correct fuse.
Replace only with a fuse of the same rat-
ing and type.
The wires in the mains lead are coloured
in accordance with the following code:
Green and yellow = Earth,
Blue = Neutral,
Brown =
Live.
As the colours of the wires in the mains
lead for the appliance may not correspond
with the coloured markings identifying the
terminals in your plug, proceed as follows:
1. The wire which is coloured green and
yellow must be connected to the terminal
marked E (Earth) or coloured Green.
2. The wire which is coloured blue must
be connected to the terminal marked N
(Neutral), or coloured Black.
3. The wire which is coloured brown must
be connected to the terminal marked L
(Live), or coloured Red.
The plug and socket must be accessible
after installation. Should the mains lead of
the appliance ever require replacing, this
must be carried out by a qualified electri
-
cian who will replace it with a lead of the
same size and temperature rating.
Important: - ensure that you route all
mains and electrical cables and flexible
tubing well clear of any adjacent heat
source.
Under no circumstances should the mains
electric cable be allowed to come into
contact with the vertical oven flue tubes
on the rear of the appliance.
E (Earth)
Green/Yellow
N (Neutral)
Blue
L (Live)
Brown