Connect to the gas supply
1. The inlet to the appliance is
1
⁄
2
” BSP
internal situated at the rear top right
corner.
2. Fit the bayonet connection to the
wall in the shaded area as shown.
3. Use a 900 mm - 1125 mm length of
flexible connector and make sure it
does not block the fan inlet and can-
not come into contact with moving
parts of the cabinetry, eg; drawers
and doors.
4.
Natural Gas
Flexible connections should be to
B.S. 699. Parts of the appliance
likely to come into contact with a
flexible connecter have a tempera-
ture rise less than 70
o
C.
LP Gas
For flexible connections use a bayo-
net type hose, suitable for use on LP
Gas up to 50 mbar pressure and
70
o
C temperature rise. The flexible
hose should be coloured black with
a red stripe, band or label. If in
doubt, contact your supplier.
5. Rigid connections must be accessi-
ble to disconnect for servicing. Cut
a 150 mm square hole in the right
hand rear corner of the support
shelf for the supply pipe.
6. Make sure all connections are gas
sound.
Secure appliance into housing
unit
1. Open the oven door.
2. Use 2 screws through the 2 top
corner holes to secure the appliance
to the housing.
INSTALLATION INSTRUCTIONS
Rear
Wall
60 mm
100
mm
150 mm
square
19