The cooling fan
The cooling fan keeps the doors,
fascia and control knobs cool during
normal use. When a burner is
operated, you should hear the cooling
fan switch on automatically and be
able to feel air evacuating from the
appliance vents just below the fascia.
The cooling fan will continue to
operate for up to 10 minutes after
turning off the burners. This is normal.
If there is no such indication that the
fan is operating, the appliance will
require servicing. DO NOT USE THE
APPLIANCE UNTIL IT HAS BEEN
SERVICED. Switch the appliance off at
the mains and contact customer support.
Glass door panels
To meet the relevant Standards of
Domestic cooking appliances, all the
glass panels on this appliance are
toughened to meet the fragmentation
requirements of BS3193. This ensures
that, in the unlikely event that a panel
breaks, it does so into small fragments
to minimise the risk of injury.
Please take care when handling, using
or cleaning all glass panels as any
damage to the surfaces or edges may
result in the glass breaking without
warning or apparent cause at a later
date. Should any glass panel be
damaged, we strongly recommend
that it is replaced immediately.
To replace a light bulb
Caution:
Switch off the electricity
supply, to remove the risk of electric
shock. Wait until the oven /grill is
cool before removing the shelves.
With a large flat bladed screwdriver
or coin, prise off the lamp glass cover.
Unscrew the bulb and replace.
replace lens cover.
Please note that oven light bulbs are
not covered by guarantee.
Ventilation
The use of a gas cooking appliance
results in the production of heat and moisture
in the room in which it is installed.
Ensure that the kitchen is well ventilated;
keep natural ventilation holes open or
install a mechanical ventilation device
(mechanical ventilator).
Prolonged intensive use of the appliance
may call for additional ventilation, for
example opening a window, or more
effective ventilation, for example
increasing the level of mechanical
ventilation where present.
This appliance is not connected to a
combustion products evacuation device. It
must be installed and connected in
accordance with current installation
regulations. Particular attention must
be given to the relevant regulations
regarding ventilation.
3
INTRODUCTION
23894 02 - Q901G/900G RS2 03/04/2001 14:19 Page 5
Summary of Contents for 900G
Page 2: ...23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 2 ...
Page 43: ...NOTES 41 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 43 ...
Page 44: ...NOTES 42 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 44 ...
Page 45: ...NOTES 43 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 45 ...
Page 47: ...23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 47 ...
Page 48: ...08 23894 02 2000 RS2 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 48 ...