36
Before servicing:
Disconnect the gas
and electrical supplies.
After servicing:
Check gas soundness.
1. Remove appliance from housing
a. Disconnect the electricity supply.
b. Open the grill door and unscrew the 2
screws through the front frame.
c.
Pull forward & out onto a suitable
surface.
d. Disconnect the gas supply inlet from
the rear wall.
2. Fascia panel
d. Pull off control knobs & programmer
buttons.
b.
Q901G -
From the rear, remove the
4 screws (2 each end) securing the
fascia to the front frame.
The fascia can now be pulled clear,
complete with programmer.
b.
900G -
Open the grill door & support
the facia glass while unscrewing its
securing screws from under the facia.
Hold down the bottom edge of the
glass, pull forward slightly & then down,
to release it from its locating clips.
3. Cooling fan
a. Remove appliance from housing (1).
b. Unscrew the top / back panel
securing screws.
c.
Ease the panel backwards to gain
access to the fan. Disconnect the 2
wires from the fan.
d. Support the fan and remove the four
fixing screws which secure the fan to
the panel.
4. Ignition generator
a. Remove appliance from housing (1).
b. Unscrew the top / rear panel securing
screws. Ease the panel backwards,
remove both fan leads & lift panel clear.
c.
Unscrew the 2 screws which secure
the generator to the inner rear panel.
d. Disconnect the leads.
e. Re-connect leads to new generator.
5. Oven / grill switches
a. Remove appliance from housing (1).
b. Unscrew the top / rear panel securing
screw. Ease panel backwards, remove
both fan leads & lift panel clear.
c.
Remove the fascia glass panel (2).
d. Disconnect the outlet tubing
connection from the thermostat and
the grill tap.
e. Remove the two screws securing the
gas rail support bracket to the front
frame.
f.
Remove the 2 screws securing the gas
rail inlet pipe to the rear panel and lift
the gas rail assembly away from the
appliance.
g. Remove circlip from grill tap spindle to
allow removal of switch.
h. Slide switch off the thermostat spindle.
6. Door frame(s)
a. The oven inner glass panel is not
secured to the frame and can be
removed. Hold the top and bottom
edges of the glass and slide out.
b. Insert 2 screws through the inner holes
in the door hinge arms (to stop the
door from springing up).
c.
With the aid of a small screwdriver,
prise out both inner door glass stops,
near the bottom of each side
extrusion.
d. Slide door forwards off the plastic
hinge blocks.
SERVICING INSTRUCTIONS
23894 02 - Q901G/900G RS2 03/04/2001 14:19 Page 38
Summary of Contents for 900G
Page 2: ...23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 2 ...
Page 43: ...NOTES 41 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 43 ...
Page 44: ...NOTES 42 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 44 ...
Page 45: ...NOTES 43 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 45 ...
Page 47: ...23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 47 ...
Page 48: ...08 23894 02 2000 RS2 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 48 ...