56
7 C LE A NING
NOTICE
Material damage caused by
improper cleaning
Water may penetrate and damage
the Vaporizer or USB cable
• Do not immerse in water or
other liquids
• Do not clean with a direct water
or steam jet or compressed
air
7.2 Screens
X
After each vaporization, clean the
Screens with the enclosed Clean-
ing Brush.
7.3 Filling Chamber
i
It is necessary to clean the Filling
Chamber as soon as the lower
Screen is clogged.
7.3.1 Removing the lower Screen
X
Remove the lower Screen by press-
ing it along the groove in the Filling
Chamber using the Filling Cham-
ber Tool. This causes the lower
Screen to bulge and detach from
the groove.
7.3.2 Cleaning
X
Clean the Filling Chamber with a
cotton swab soaked in isopropyl
alcohol.
i
Make sure that no isopropyl alcohol
drips into the interior of the device.
7.3.3 Installing the lower Screen
X
Curve the lower Screen. I
X
Insert the lower Screen into the Fill-
ing Chamber with the curved side
facing upwards.
X
Using the Filling Chamber Tool,
press the screen flat into the pro
-
vided groove.
7.4 Vaporizer and USB Cable
X
Disconnect the USB cable from the
power source.
X
Switch off the Vaporizer.
X
Clean the housing of the Vapor-
izer and the USB cable only dry
or at most with a damp cloth if