background image

11

10

4. OVERVIEW OF PLANTS

  

Portion of the Temperature- 

 

Plant name  Botanical name 

plant used setting 

Eucalyptus  

Eucalyptus globulus 

the leaves  

1 / 130°C (266°F)  

Hops 

Humulus lupulus 

the cones 

3 / 154°C (309°F) 

Chamomile 

Matriarca chamomilla 

the blossoms 

6 / 190°C (374°F) 

Lavender 

Lavandula angustifolia  the blossoms  

1 / 130°C (266°F) 

Lemon balm  

Melissa officinalis  

the leaves  

2 / 142°C (288°F) 

Sage  

Salvia officinalis  

the leaves  

6 / 190°C (374°F) 

Thyme  

Thymus vulgaris  

the herb  

6 / 190°C (374°F) 

Below is an overview of the plants that 
are suitable for vaporization in the 

PLENTY

 Vaporizer. 

The aromas and fragrances from the 
plant materials listed below may be 
vaporized.*
Any other use is inappropriate and po-
tentially dangerous. 
Information and up to date news 
about plants suitable for vaporization 
will be published on 

www.storz-bick-

el.com

2. SAFET Y RECOMMENDATIONS

The 

PLENTY

 Vaporizer releases fra-

grances or aromas from the herbs 
and other plant materials listed below. 

These aromatic substances are re-

leased through vaporization by heated 

air, and may be directly inhaled. 

 

WARNING: 

Please consult your doctor 
or pharmacist if you have any 

medical concerns. It is possible that 
some plants may cause allergic reac-
tions for the user. If this occurs, it is 
urgently recommended to refrain from 
further use of such plants. 

best possible way for your personal re-
quirements. 
The 

PLENTY

 Vaporizer is not a medical 

device and is not intended to diagnose, 
treat, cure or prevent any disease. 
*This statement has not been evalu-
ated by the FDA. The 

PLENTY

 Vapor-

izer is not a medical device and is not 
intended to diagnose, treat, cure or 
prevent any disease.

The device may only be used with the 

recommended vaporizing media. The 
use of other substances can present 
a health risk.

The 

PLENTY

 Vaporizer is not intended 

for medical/therapeutic purposes. 

Only use the plant parts which are 
found in this list and which have been 
verified according to the regulations 
of the European or any other pharma-
copoeia with regard to genuineness, 
purity and pathogenic germs. You can 
purchase such plants or plant parts in 
pharmacies.* 
It is important to observe the following 
instructions in order to set the 

PLENTY

 

Vaporizer with the plant material in the 

3. INTENDED USE

The heat exchanger inside 
the Filling Chamber Thread-
ing and the Filling Chamber 

Cylinder are made of metal and be-
come hot during operation. Do not 
touch them when they are hot!

Caution! Hot surface! 

The manufacturer is not re-
sponsible for any damage 
or personal injury caused

by inappropriate, incorrect or irre-
sponsible use. 

 

Only use original Storz & Bickel ac-
cessories and spare parts. 

Summary of Contents for Plenty

Page 1: ...INSTRUCTIONS FOR USE Read carefully before using the device and save these instructions STORZ BICKEL GMBH CO KG...

Page 2: ...16 8 Filling the Filling Chamber 18 9 Application 23 10 Disassembling Cleaning and Assembling 25 10 1 Disassembling and Reassembling the PLENTY Vaporization Unit 25 10 2 Disassembling the Mouthpiece...

Page 3: ...OVERVIEW PLENTY HOT AIR GENERATOR Mouthpiece Thermometer Filling Chamber Threading Vaporization Unit comprising Auto off Release Handle Power Switch Temperature Adjustment Wheel Ventilation Slots Cont...

Page 4: ...the necessity of disposing of this product separately 2 SAFETY RECOMMENDATIONS 2 SAFETY RECOMMENDATIONS Read the following safety recommendations thor oughly and carefully before using the device The...

Page 5: ...izer to be used by children or unqualified persons cident prevention measure is not taken The power cord must be unwound over its entire length avoid roll ing up and overlapping the power cord It must...

Page 6: ...e user If this occurs it is urgently recommended to refrain from further use of such plants best possible way for your personal re quirements The PLENTY Vaporizer is not a medical device and is not in...

Page 7: ...of children or unqualified persons In Case of Problems Immediately unplug the power cord and ensure that no one can connect the Hot Air Generator to the mains supply again without this being no ticed...

Page 8: ...tes depend ing on the temperature set Press the auto off release handle to activate the heating process 7 CO M MISSIO NING AND OPER ATIO N 6 THE H OT AIR GENER ATOR PLENTY Vaporization temperature sca...

Page 9: ...to off release handle again to restart heating For technical reasons it is not possible to measure the tem perature in the Filling Cham ber during the inhalation process The thermometer measures the t...

Page 10: ...crushed or ground plant material Always fill the Filling Chamber completely up to the upper edge This prevents the va porization material from shifting when the Hot Air Generator is not held up right...

Page 11: ...8 FILLING THE FILLING CHAMBER If the Filling Chamber is not to be filled completely it is recommended to place the included Liquid Pad over the herbs and then screw the cap with the Cooling Coil onto...

Page 12: ...lling Chamber with Cool ing Coil and Mouthpiece onto the Hot Air Generator and heat it up This ensures that both the Filling Cham ber and the vaporization material are preheated and the vaporizing can...

Page 13: ...Generator unplug the power cord and let it cool down be fore putting the device away 9 APPLICATION 10 DISASSEMBLING CLEANING AND ASSEMBLING Mouthpiece Upper Tubing Section long Cooling Coil Lower Tubi...

Page 14: ...mpo nent parts to dry properly Mouthpiece Upper Tubing Section long Cooling Coil Cooling Coil Filling Chamber Cap Upper Screen Lower Tubing Section short 10 DISASSEMBLING CLEANING AND ASSEMBLING 10 3...

Page 15: ...sure the posi tioningsurfacesareorientedcorrectly as shown in the detailed illustration Lower Screen Filling Chamber Cylinder Filling Chamber Housing Push the Filling Chamber Cylinder upwards out of...

Page 16: ...the Product is physically deliv ered to the Customer s site and is val id for thirty six 36 months thereafter Company does not authorize any per son or party to assume or create for it any other oblig...

Page 17: ...ity for gross negligence or willful misconduct or do not allow implied warranties to be excluded the limitation or exclusion of warran ties remedies damages or liability set forth above are intended t...

Page 18: ...KEL GmbH Co KG PAL 30 202 E 09 2016 Subject to alterations All rights reserved STORZ BICKEL GMBH CO KG In Gruben cker 5 9 78532 Tuttlingen Germany STORZ BICKEL AMERICA INC 1078 60th Street Suite A Oak...

Reviews: