29
28
10. DISASSEMBLING, CLEANING AND ASSEMBLING
Push out the Filling Chamber Cylinder
Push out the lower Screen
Put in the Screen into the Filling Cham-
ber from the topside.
Screw the Filling Chamber Cap with
Cooling Coil and Mouthpiece onto the
Filling Chamber.
Filling Chamber Cylinder, Filling Chamber
Housing, Positioning Surfaces
10.4. Disassembling the
Filling Chamber
Push the lower Screen upwards out of
the Filling Chamber Cylinder.
10.5. Assembling the Filling
Chamber
Place the Filling Chamber Cylinder into
the Filling Chamber Housing from above,
and turn it so that the flattened position-
ing surfaces are located in the intended
orientation within the Filling Chamber
Housing. Push the Filling Chamber Cyl-
inder in until it latches into the Filling
Chamber Housing. Make sure the posi-
tioning surfaces are oriented correctly, as
shown in the detailed illustration.
Lower Screen
Filling Chamber
Cylinder
Filling Chamber
Housing
Push the Filling Chamber Cylinder
upwards out of the Filling Chamber
Housing.
Voltage:
220 - 240 V / 50 - 60 Hz
or 100 - 120 V / 50 - 60 Hz
The voltage specification is located on
the type label of the
PLENTY
Hot Air
Generator.
Power required by
PLENTY
: 110 W
Vaporization temperature:
adjustable between approx.
130°C- 202°C / 266°F - 396°F
Dimensions: 20.0 x 15.5 x 6.0 cm
(7.9 x 6.1 x 2.4 inch)
Weight: approx. 0.7 kg (1.5 lbs)
Safety category I (electrically
grounded)
Please unplug to disconnect from the
mains current.
Subject to technical changes.
Patents:
EP 2 599 512, US 9,272,103
Manufacturer
Storz & Bickel GmbH & Co. KG
In Grubenäcker 5-9
78532 Tuttlingen, Germany
11. TECHNICAL SPECIFICATIONS
12. DECLARATION OF CONFORMIT Y
The devices comply with the following
EC Directives:
�
Low Voltage Directive
73/23/EWG
�
Electromagnetic Compatibility
89/336/EWG