10. DISASSEMBLING, CLEANING AND ASSEMBLING

Pull the Mouthpiece away from the Cooling 
Coil 

The Vaporization Unit may be eas-
ily disassembled and reassembled 
for cleaning in a few seconds. The 
Mouthpiece, Filling Chamber, and cap 
components may also be cleaned in a 
dishwasher. 
However, the Screens, Mouthpiece, 
and Tubing Sections are very small, 
and may be lost if placed in a dish-
washer. 
 

Do not immerse any plastic 

components in ethanol or al-
cohol for longer than an hour. 

Extended contact with ethanol or al-
cohol may lead to discoloration or em-
brittlement of plastic parts. 
After cleaning, check all component 
parts for surface damage, tears, sof-
tening or hardening, impurities, dis-
tortion and discoloration and set dam-
aged component parts aside.

10.2.  Disassembling the  
 Mouthpiece 

1.  Pull the Mouthpiece and the Tubing 

Section off of the Cooling Coil with 
a gentle twist.

2.  Pull the Tubing Section off of the 

Mouthpiece with a gentle twist. 

Reassemble in reverse order. 
Before assembling allow all compo-
nent parts to dry properly. 

Mouthpiece

Upper Tubing  

Section (long)

Cooling Coil

Cooling Coil

Filling  

Chamber Cap

Upper Screen

Lower Tubing  

Section (short)

10. DISASSEMBLING, CLEANING AND ASSEMBLING

10.3.   Disassembling the Filling  
 

Chamber Cap

Push out the upper Screen with help of the 
Cleaning Brush

Pull the Cooling Coil out of the Filling 
Chamber Cap

Pull the Cooling Coil out of the Filling 
Chamber Cap with a gentle twist, and 
then remove the Tubing Section from 
the Cooling Coil. 

Push the upper Screen out of the Fill-
ing Chamber Cap from above, by us-
ing (for example) the handle of the 
included Cleaning Brush. 

Reassemble in reverse order. 
The upper Screen must be inserted 
carefully into the groove provided. 
Disregarding this may allow plant 
particles to enter the Cooling Coil, so 
blocking this or be inhaled. 

10.3.1. Cleaning the Cooling Coil 

Place the Cooling Coil in a glass and 
immerse it completely in alcohol (eth-
anol), cover the glass, and let it soak 
overnight. 
Repeat this process until the inside of 
the Cooling Coil is completely clean, 
then rinse it carefully with water.

 

Warning! Alcohol is flamma-

ble and may easily ignite. 

 

Sets of new Cooling Coils may 
be ordered from 

www.storz-

bickel.com

Summary of Contents for Plenty

Page 1: ...INSTRUCTIONS FOR USE Read carefully before using the device and save these instructions STORZ BICKEL GMBH CO KG...

Page 2: ...16 8 Filling the Filling Chamber 18 9 Application 23 10 Disassembling Cleaning and Assembling 25 10 1 Disassembling and Reassembling the PLENTY Vaporization Unit 25 10 2 Disassembling the Mouthpiece...

Page 3: ...OVERVIEW PLENTY HOT AIR GENERATOR Mouthpiece Thermometer Filling Chamber Threading Vaporization Unit comprising Auto off Release Handle Power Switch Temperature Adjustment Wheel Ventilation Slots Cont...

Page 4: ...the necessity of disposing of this product separately 2 SAFETY RECOMMENDATIONS 2 SAFETY RECOMMENDATIONS Read the following safety recommendations thor oughly and carefully before using the device The...

Page 5: ...izer to be used by children or unqualified persons cident prevention measure is not taken The power cord must be unwound over its entire length avoid roll ing up and overlapping the power cord It must...

Page 6: ...e user If this occurs it is urgently recommended to refrain from further use of such plants best possible way for your personal re quirements The PLENTY Vaporizer is not a medical device and is not in...

Page 7: ...of children or unqualified persons In Case of Problems Immediately unplug the power cord and ensure that no one can connect the Hot Air Generator to the mains supply again without this being no ticed...

Page 8: ...tes depend ing on the temperature set Press the auto off release handle to activate the heating process 7 CO M MISSIO NING AND OPER ATIO N 6 THE H OT AIR GENER ATOR PLENTY Vaporization temperature sca...

Page 9: ...to off release handle again to restart heating For technical reasons it is not possible to measure the tem perature in the Filling Cham ber during the inhalation process The thermometer measures the t...

Page 10: ...crushed or ground plant material Always fill the Filling Chamber completely up to the upper edge This prevents the va porization material from shifting when the Hot Air Generator is not held up right...

Page 11: ...8 FILLING THE FILLING CHAMBER If the Filling Chamber is not to be filled completely it is recommended to place the included Liquid Pad over the herbs and then screw the cap with the Cooling Coil onto...

Page 12: ...lling Chamber with Cool ing Coil and Mouthpiece onto the Hot Air Generator and heat it up This ensures that both the Filling Cham ber and the vaporization material are preheated and the vaporizing can...

Page 13: ...Generator unplug the power cord and let it cool down be fore putting the device away 9 APPLICATION 10 DISASSEMBLING CLEANING AND ASSEMBLING Mouthpiece Upper Tubing Section long Cooling Coil Lower Tubi...

Page 14: ...mpo nent parts to dry properly Mouthpiece Upper Tubing Section long Cooling Coil Cooling Coil Filling Chamber Cap Upper Screen Lower Tubing Section short 10 DISASSEMBLING CLEANING AND ASSEMBLING 10 3...

Page 15: ...sure the posi tioningsurfacesareorientedcorrectly as shown in the detailed illustration Lower Screen Filling Chamber Cylinder Filling Chamber Housing Push the Filling Chamber Cylinder upwards out of...

Page 16: ...the Product is physically deliv ered to the Customer s site and is val id for thirty six 36 months thereafter Company does not authorize any per son or party to assume or create for it any other oblig...

Page 17: ...ity for gross negligence or willful misconduct or do not allow implied warranties to be excluded the limitation or exclusion of warran ties remedies damages or liability set forth above are intended t...

Page 18: ...KEL GmbH Co KG PAL 30 202 E 09 2016 Subject to alterations All rights reserved STORZ BICKEL GMBH CO KG In Gruben cker 5 9 78532 Tuttlingen Germany STORZ BICKEL AMERICA INC 1078 60th Street Suite A Oak...

Reviews: