6. Cleaning, Care and Maintenance
– Remove the filter, which protects the fan against dust and dirt, from time to time
and clean it.
– After several hours of operation, some droplets of condensation will have formed
at the nozzle. That is normal and not a malfunction.
Please note
: Remove fluid droplets at the nozzle only when the machine has com-
pletely cooled off. During operation the nozzle gets very hot!
– Do not let the
Unique 2.1
run without any fluid as the pump will run dry.
– Check the state of the fluid filter [12] from time to time and clean or replace it when
necessary.
¤ fb[Wi[dej[Pj~{w { | wy~{z { ~w{ x{y{w{z7Y{w{B
available on the market, can damage the vaporizer! We cannot grant warranty in
this case.
7. Troubleshooting
Trouble:
The pump runs, but little or no haze is produced.
Cause:
The pump sucks no or too little fluid.
· Check whether the canister is empty
· Check whether the brass collar is properly connected with the brass
coupling
· Check whether the fluid filter in the canister is clogged
· Check whether the fluid tube is twisted or defective
Trouble:
The yellow LED at the machine does not light up (only when running
via DMX)
Cause:
Connection from the machine to the desk is faulty.
· Check whether the plug is plugged in correctly
· Check whether the cable is defective
· Check whether the DMX start address is adjusted correctly
Trouble:
During operation the
Unique 2.1
fail to work for a long time
Cause:
The overtemperature protection device is activated.
· Check whether the fan is clogged