AXS Strikemaster 

Engineering Manual 

AXS Strikemaster Programming and Operation Manual                                          May 2013     Page 1 of 22 

For more  information visit 

www.storm-interface.com

   © Copyright Storm Interface. 2013. All rights reserved 

 

 
 

 
 

 

Summary of Contents for AXS Strikemaster

Page 1: ...Strikemaster Engineering Manual AXS Strikemaster Programming and Operation Manual May 2013 Page 1 of 22 For more information visit www storm interface com Copyright Storm Interface 2013 All rights reserved ...

Page 2: ...r Strike Time 13 Programming Set the Penalty Time for Invalid Code 14 Other Features 15 Connect a Remote Exit Egress Switch 15 Connect an External Alarm 15 Control a Second Door 15 Enable Door Monitoring Door 1 only 16 Activating the Operator Under Duress Alarm 16 F A Q s 17 1 The door is locked when it should be open and open when it should be locked 17 2 The Keypad appears to be have lost its en...

Page 3: ...es and Benefits A range of access control keypads providing rapid and reliable access control in high traffic applications Constructed to withstand hard use and abuse the keypads can be fitted in exposed unsupervised locations Up to 50 different 4 5 or 6 digit pin codes can be programmed and each code can be set to trigger an electric lock or strike for a pre set time One or two door control Weath...

Page 4: ...ase Material Keytop Material DE1KT101 STORM AXS STRIKE MASTER ANTI VANDAL KEYPAD Two Relays Metal Case Metal Keytops DE2KT101 STORM AXS STRIKE MASTER ROBUST KEYPAD Two Relays Polymer Case Polymer Keytops White DEPLXT201 PLX STRIKE MASTER STORM 1000 SERIES Two Relays Polymer Case Metal Keytops DR2KT201 STORM AXS STRIKE MASTER ROBUST SINGLE DOOR KEYPAD One Relay Polymer case Polymer Keytops Black RC...

Page 5: ...013 Page 5 of 22 For more information visit www storm interface com Copyright Storm Interface 2013 All rights reserved Dimensions What s in the Box Keypad DE1K shown Back Box Gasket Programming Chart Security Screws Driver Bit for Security Screws Tamper Bracket Screws Plugs for Backbox fixing ...

Page 6: ...positioning the case over the fixing holes A Be sure to run the cable through the hole in the gasket prior to securing the case 5 Secure the case to the surface using the fixing screws E as supplied Keypad to Casing 6 When making the electrical connections to the connector block care should be taken not to damage the thin sealing gasket C fixed to the front face of the rear case 7 Fix the keypad t...

Page 7: ...ct relay normally open or relay normally closed to suit the intended application and locking mechanism Note To achieve maximum protection against EMC RFI or damage from Electro static Discharge it is recommended that the keypad casing is earthed grounded via the screw terminal attached to the metal shield on the rear face of the keypad This terminal is identified by a symbol It is recommended that...

Page 8: ... outdoor or indoor access points to establish and maintain familiarity with the keypad features Summary of Features Up to 50 user programmable entry codes Entry Code indexing system provides a directory of authorised code holders and permits secure allocation and re allocation of entry codes 4 5 or 6 digit entry codes One or two door control Anti tamper alarm Entry code entered under duress alarm ...

Page 9: ...ght green to signify that the door lock is in a released or open condition Programing Mode To enter programming mode it is required that the operator logs on by entering the engineer s code When logging on the engineer s code must be preceded by the key If the code is correct the LED will start flashing red and green alternately to signify that the operator has logged on and that the keypad is in ...

Page 10: ...ngineer s code is not known power down the keypad for a period of not less than three seconds Power up the keypad and within a two minute period enter the Engineer reset code Do not enter any other digits before entering this code The keypad s LED will then begin flashing to indicate that the keypad is in programming mode Enter 4 to select a new engineer s code If code is not known Power Down then...

Page 11: ... digit reference known as the Code Index Number The code index number allows an authorised holder of the engineer s code to remove entry codes by keying in the code index number without having knowledge of the actual entry code It also means that a written record of valid code holders can be kept without recording the actual entry codes c Prior to operation of a second door relay 2 must be set for...

Page 12: ...ing codes remove a single code or remove all codes Remove an user code Enter To add an entry code Enter Enter the 2 digit index number max 50 Enter Select door and mode of entry required for this entry code Enter 4 5 or 6 to correspond to no of digits in code Enter or or Enter new code Remove all user codes Enter Enter Enter Index number where code is to be removed Enter Door 1 Timed Enter Door 1 ...

Page 13: ...n seconds 01 98 Listen for the accept beep NOTE If the strike time is required to be set to zero secs then you must enter 99 An entry of 00 will give you a strike time of 1 second ii Setting the Door 2 Strike Time To set the Door 2 strike time log on then enter 6 to select the Door 2 Strike Time Set Up function Listen for the accept bleep Then enter a two digit number to set the duration of the st...

Page 14: ...ed to deter any attempt to gain unauthorised access by guessing the format of a valid code To set the Invalid Code Penalty Time log on to Programming Mode then enter 7 to select the Invalid Code Penalty Time function Listen for the accept bleep Then enter a two digit number to set the duration of the Penalty Time in seconds 01 99 Listen for the accept bleep Enter 0 to Log Off Listen for the accept...

Page 15: ...n be re closed or a forced door can be closed then keying in a valid Entry Code will silence and reset the alarm If for any reason the cause of the alarm can not be rectified e g The keypad has been forced away from the wall or the door has been damaged and can not be closed then the alarm can be silenced by keying in a valid Entry Code twice 2 times When the alarms have been silenced in this way ...

Page 16: ...nected between terminals 9 and 1 0V Return and the Door Sensor This disables the door forced alarm feature To utilise the door sensor remove the hard wire bridge and connect the door sensor to terminals 1 and 9 Activating the Operator Under Duress Alarm The Operator Under Duress Alarm can be activated at any time by prefixing a valid entry code with the numbers 9 1 Note if there is any possibility...

Page 17: ...ise 8 The door opens for too long 9 What are the door release relays rated at 1 The door is locked when it should be open and open when it should be locked Check the type of lock that is installed Does it require power to open it or power to lock it This will determine which keypad terminals should be connected If the lock requires power to open it then the lock should be connected to zero volts a...

Page 18: ...o 99 seconds can be programmed If the above situation is suspected the following routine should be carried out 1 Check that all connections to the keypad power supply and locking device are still secure Ensure that the suppresser Metal Oxide Varistor MOV is connected across the lock terminals Ideally this should be located as close to the lock as possible 2 Reset a workable strike time as follows ...

Page 19: ...nd fit a separate bell push button The bell connection terminal No 8 is an open collector gate The bell should be connected to the Strikemaster keypad via a relay The coil on the relay should be connected to the positive supply connection terminal No 2 and the bell connection terminal No 8 When the bell key is pressed a transistor linked to terminal 8 will be driven low This will allow current fro...

Page 20: ...ts will cause relay 1 connections to change to open circuit this could be used to switch off the alarms The second 4 digits will then open the door Please note This configuration may not be suited for applications where the driver may have to enter the door on more that one occasion This is because the alarms will toggle on and off each time the 8 digit entry code is pressed so there is a danger t...

Page 21: ...ove all user codes Enter Enter Enter Index number where code is to be removed Enter Door 1 Timed Enter Door 1 Latched Enter Door 2 Timed Enter Door 2 Latched Enter Index allocated delete fields Index allocated try another Index No Door 1 Enter To set door strike times Door 2 Enter Enter Strike Time in seconds Enter To reset Invalid Penalty Time Enter Enter Penalty Time in seconds Enter Alarm Enter...

Page 22: ...ngineering Manual AXS Strikemaster Programming and Operation Manual May 2013 Page 22 of 22 For more information visit www storm interface com Copyright Storm Interface 2013 All rights reserved Programming Quick Reference ...