Strikemaster ES Manual
Strikemaster ES Engineering Manual Page 16 of 16 For more information visit
www.storm-interface.com
Rev 2.1 June 2015
© Copyright Storm Interface. 2015. All rights reserved
Keypad Setup
The keypad is factory configured. The slide switch must be left in the RUN position.
Power Supply
Power
- 12V DC only
Ground
–
0V
Data Connection
Data D0 &
Data D1
Keypad Tamper Alarm
The keypad will transmit a PING packet (0x3C) every few seconds to the SCU. If the SCU does not receive
a ping packet for 30 seconds then the SCU will output alarm signal.
‘Operator Under Duress’ Alarm
The Operator Under Duress Alarm can be activated at any time by prefixing a valid entry code with
the numbers 9 1. The door will open and the alarm will be activated.
Note: if there is any possibility that this feature will be used, any visible or audible alarm
indicators must be located out of audible and visual range of any attacker or intruder.
The
alarm
can
be
cancelled
by
entering
a
valid
entry
code
twice.
Indicator Input
The indicator input will control the keypad buzzer and green led depending on the length of pulse on the indicator
input. The following functions are provided:
10ms Pulse
-
Valid pin code was received. (green led + confirm tone on buzzer for 1s)
20ms Pulse
-
Invalid pin code was received. (red led + error tone on buzzer for 1s)