7 Set
Penalty
Time
The SCU can be set up so that if 3 invalid entry codes are entered in succession, a valid code cannot be entered until
the penalty time has elapsed. The penalty time can be from zero to 39 seconds.
1. To set up or change the penalty time,
first log into programming mode. The LED on keypad A will flash red to
indicate that they system is in programming mode and the buzzer on the controller will beep.
2.
Press ‘7’.
3.
Input the penalty time as a 2 digit number (00 – 39).
4.
To log out of programming mode press ‘0’ or to continue programming, press the required programming
option number.
9
Reset to Factory Defaults
Selecting this option will result in the following:
The programmed engineer’s code will erased
All entry codes will be erased
Entry code length will be reset to 4 digits
Door strike timeout for door A and B will be reset to 5 seconds
Penalty time will be reset to 15 seconds
1.
To reset the SCU to its factory defaults,
first log into programming mode. For this particular option this must
be done by pressing the red button on the controller and then inputting the default engineer’s code into
keypad A. Once in programming mode, the LED on keypad A will flash red and the buzzer on the controller
will beep.
2. Press
‘9’.
3. Press
‘1’.
4. Then confirm the reset by pressing ‘1’ again. This will reset the system to its factory defaults. To cancel the
reset and leave the system as is, press ‘0’.
5.
To log out of programming mode press ‘0’ or to continue programming, press the required programming
option number.