Strikemaster ES Manual
Strikemaster ES Engineering Manual Page 13 of 13 For more information visit
www.storm-interface.com
Rev 2.1 June 2015
© Copyright Storm Interface. 2015. All rights reserved
Record
Card
There is a record card inside the cabinet door on the EU Version
This can be used to record Engineer Code and Connections
See Example below
Strikemaster ES
SYSTEM INSTALLED BY
ANTHONY BLAIR
………………………………
1 May 2014
ON …………………………
CONTACT
07904 910656
ENTRY CODES SET TO
4
…….. DIGITS
MASTER ENGINEER CODE
251280 5 Nov 2008
…………
569358 1 Jan 2012
………………….
…………………
………………..
ENTRY CODES LIST
HELD BY
CHERIE
……………….
Firmware Rev 2.0
NOTES
DOOR 'A'
NO. 10 WINE CELLAR
A
+12V TO LOCK
RED - MAGLOCK
B RELAY
NC
BLUE
C
RELAY COM – LINK TO 12v IF POWERED
GREEN
D RELAY
NO
E
GROUND
BLACK
1
+12V TO KEYPAD
BLUE/WHITE
2 KEYPAD
LED/BUZZER
RED/WHITE
3
KEYPAD D0
GREEN/WHITE
4 KEYPAD
D1
ORANGE/WHITE
5 GROUND
YELLOW/WHITE
6
DOOR SENSOR
PURPLE
7 EXIT
SWITCH
RED
8
GROUND
BLACK
DOOR ‘B’
A
+12V TO LOCK
B
RELAY NC
C
RELAY COM - LINK TO 12v IF POWERED
D
RELAY NO
E
GROUND
1
+12V TO KEYPAD
2
KEYPAD LED/BUZZER
3
KEYPAD D0
4
KEYPAD D1
5
GROUND
6
DOOR SENSOR
7
EXIT SWITCH
8
GROUND
ALARMS
NOISY SIREN
IN CABINET OFFICE
1
+12V
2
+12V
RED
3
RELAY NC ALARM
YELLOW
4
RELAY COM ALARM - 12v IF POWERED
5
RELAY NO ALARM
BLACK
6
BELL
BLUE
7
GROUND
8
GROUND
LINK