Operating in Manual Mode
3-20
Eighth Edition
95698
Dismounting a Cartridge from a Drive
To dismount a cartridge from a drive:
1. Obtain the drive number from the customer server console and place the drive
offline.
2. Open the LSM front door by using a latch key to unlock the top and bottom
.
3. Locate the desired drive.
4. Make sure that the job is finished.
5. Make sure that the Operate Handle indicator is on. If it is not, press the Unload
button on the drive to unload the drive. The indicator will turn on.
6. Push the shuttle all the way back, pause for three seconds, then release the
shuttle.
Note:
If the cartridge does not come out of the drive, remount the cartridge by
releasing it from the shuttle latch under the right side of the cartridge. Then
push the cartridge into the drive, and lower the handle. If this fails, the tape
leader might be dislodged and require rethreading.
7. Remove the cartridge from the drive.
8. Properly store the cartridge outside the LSM. (Refer to
Returning the LSM to Online Status
To place the LSM online for automated operations:
1.
Make sure that the drive shuttle Operate Handle indicator is on and the
handle is up
.
2. Close and lock the LSM doors. The robot will perform an audit of the cells.
Summary of Contents for 9714
Page 1: ...9714 Library Storage Module Hardware Operator s Guide Document 95698...
Page 2: ......
Page 3: ...9714 Library Storage Module Hardware Operator s Guide...
Page 6: ...Summary of Changes iv Eighth Edition 95698 This page intentionally left blank...
Page 10: ...Figures viii Eighth Edition 95698 This page intentionally left blank...
Page 12: ...Tables x Eighth Edition 95698 This page intentionally left blank...
Page 16: ...Obtaining Information xiv Eighth Edition 95698 This page intentionally left blank...
Page 28: ...AUTO CLEAN Feature 1 8 Eighth Edition 95698 This page intentionally left blank...
Page 58: ...Customer Initiated Maintenance 4 2 Eighth Edition 95698 This page intentionally left blank...
Page 72: ...Index Index 4 Eighth Edition 95698 This page intentionally left blank...
Page 75: ......