10

 

Rack-Mounting

Rack-Mounting

This section provides information on installing the StoneGate appliance 

into a rack unit. You can install the appliance into a two-post or a four-

post rack unit.

Preparing for Rack-Mounting

The appliance delivery includes the rail assemblies and the mounting 

screws you need to install the system into the rack.
Read the sections below before you begin the installation.

Choosing a Setup Location

Decide on a suitable location for the rack unit that will hold the 

appliance:

• The appliance must be situated in a clean, dust-free area that is well 

ventilated.

• Avoid areas where heat, electrical noise, and electromagnetic fields 

are generated.

• Leave enough clearance in front of the rack to enable you to open the 

front door completely (~63 cm/25 inches).

• Leave enough clearance in the back of the rack to allow for sufficient 

airflow and ease in servicing (~76 cm/30 inches).

Rack Precautions

• Ensure that the leveling jacks on the bottom of the rack are fully 

extended to the floor with the full weight of the rack resting on them.

• In single rack installation, attach stabilizers to the rack.
• In multiple rack installations, couple the racks together.
• Always make sure the rack is stable before extending a component 

from the rack.

• Extend only one component at a time—extending two or more 

simultaneously may cause the rack to become unstable.

Caution – 

Read the 

Safety Precautions

 (page 5) before proceeding.

Summary of Contents for StoneGate IPS-1205

Page 1: ...Appliance Installation Guide IPS 1205...

Page 2: ...ribed in these materials are provided pursuant to the general terms for support and maintenance services and the related service description which can be found at the Stonesoft website www stonesoft c...

Page 3: ...which can be found at the Stonesoft website Contents Installation Procedure 4 Product Documentation 4 Safety Precautions 5 Unpacking the Appliance 7 Front Panel 7 Back Panel 9 Rack Mounting 10 Connect...

Page 4: ...l Configuration page 18 Product Documentation Press F1 in any Management Client window to view the Online Help All PDF guides are available On the Management Center CD ROM in the Documentation folder...

Page 5: ...ed on electrical equipment This is to avoid making a complete circuit which will cause electrical shock Use extreme caution when using metal tools which can easily damage any electrical components or...

Page 6: ...each other An electrical discharge is created to neutralize this difference which can damage electronic components and printed circuit boards Use a grounded wrist strap designed to prevent static dis...

Page 7: ...necting the Cables page 16 The front panel indicator lights are explained below Caution Do not change the battery the battery must be replaced by authorized service personnel only Danger of explosion...

Page 8: ...s LED is illuminated when the system is operating normally Yellow The appliance is in standby mode Warning Red Overheat alert Blinks on fan failure Disk Activity Green Indicates hard drive activity wh...

Page 9: ...tate Disk SSD Drive are explained below Table 3 SSD Drive Indicators Indicator Status Explanation Power Blue A Solid State Disk is in the drive Disk Unlit This indicator is not currently used AC or DC...

Page 10: ...electrical noise and electromagnetic fields are generated Leave enough clearance in front of the rack to enable you to open the front door completely 63 cm 25 inches Leave enough clearance in the back...

Page 11: ...vent components falling off of the appliance Be sure to install an AC power disconnect for the entire rack assembly This power disconnect must be clearly marked The rack assembly must be properly grou...

Page 12: ...3 Repeat step 2 on the other side of the appliance 4 Attach each bracket to the rack with two screws through the holes in the front of the bracket one screw through the top hole and another through th...

Page 13: ...kets that attach to the appliance and two longer brackets that attach to the rack 2 Attach a short bracket to the appliance with two screws 3 Repeat step 2 on the other side of the appliance 4 Attach...

Page 14: ...one screw through the top hole and another through the bottom hole Proceed to Connecting the Cables page 16 To install the appliance with long brackets 1 Locate the two pairs of brackets in the delive...

Page 15: ...rails to the rack the rails are marked with L for left and R for right and lock the rails into position by pushing the yellow locking tabs up For additional security you can also attach the rails to...

Page 16: ...cables accordingly Cable Types Always use standard cabling methods with inline IPS use crossover cables to connect the appliance to hosts and straight cables to connect the appliance to switches hubs...

Page 17: ...the lower speed Connecting the Appliance to the Power Supply To connect the appliance to the power supply 1 Connect the power cable to the power connector on the back of the appliance 2 Plug the power...

Page 18: ...figure the engine manually See Using the Engine Configuration Wizard page 19 Configuring the Engine Automatically The automatic configuration requires that you have a suitable configuration saved on a...

Page 19: ...heck the IP addresses you have defined in the Management Client If the configuration with the USB stick still does not succeed remove the USB stick from the USB port and follow the instructions for th...

Page 20: ...ort option select the configuration file To set the keyboard layout 1 Highlight the entry field for Keyboard Layout using the arrow keys and press ENTER The Select Keyboard Layout dialog opens 2 Highl...

Page 21: ...et the rest of the OS settings 1 Type in the name of the engine 2 Type in the password for the user root This is the only account for engine command line access Note The timezone setting affects only...

Page 22: ...k Make sure that the speed duplex settings of network cards are identical at both ends of each cable Also make sure that the speed duplex settings of inline interfaces match the speed duplex settings...

Page 23: ...e can be useful during IPS appliance deployment when bypass network interface pairs on the appliance are in the Normal mode Initial bypass allows traffic to flow through the IPS appliance until the in...

Page 24: ...Client To activate the Initial Configuration 1 Highlight Switch to Initial Configuration and press spacebar to activate 2 Fill in the IP Address Netmask and Gateway to Management information accordin...

Page 25: ...third part of the configuration you select whether you want this engine to work as a Sensor an Analyzer or a combined Sensor Analyzer depending on the appliance you have purchased The selection you ma...

Page 26: ...the connection state is Connected indicating that the Management Server can connect to the node The next step is installing a security policy on the engine to replace the initial configuration you jus...

Page 27: ...the appliance does not start up with the new version it automatically switches to the previous configuration at the next reboot You can also switch back to the previously installed software version ma...

Page 28: ...reset If you decide to cancel the operation type NO and press Enter To use the appliance after a factory reset you must configure it as explained in Initial Configuration page 18 Note If the certific...

Page 29: ...ets 4 Locate the Solid State Disk drive on the appliance s back panel see the illustration in Back Panel page 9 5 Press the release button to release the lever that locks the disk into position 6 Pull...

Page 30: ...documentation See inside for further details All documentation and our technical knowledge base is available at www stonesoft com support Copyright 2010 Stonesoft Corporation Stonesoft Inc Americas He...