19
4.1 MACHINE
ADJUSTMENT
This section is intended to provide maintenance personnel
with a general understanding of machine adjustments. It
is recommended that any adjustments in this section be
made by a qualifi ed person.
4.2 PRODUCT
TEMPERATURE
ADJUSTMENT (LEFT SIDE)
A potentiometer is used to control the product tempera-
ture. To change the temperature of the product, follow
the steps below:
A.
Remove the header panel.
B.
Use a screw driver to make desired adjustment.
A label near the potentiometer will give complete
instructions.
4.3 PRODUCT
CONSISTENCY
ADJUSTMENT (RIGHT SIDE)
The operator can adjust product consistency by modify-
ing the Fine Adjustment setting on the membrane switch.
This is the only adjustment that can be made by the op-
erator without using a pass code key sequence. Product
consistency fi ne adjustment allows a 0.4 amp maximum
adjustment to the drive motor amp draw cutout. Increasing
this setting will increase the drive motor amperage cutout
and increase product consistency. Follow the instructions
below to make fi ne adjustments to product consistency.
A.
Place the Main Freezer Power switch in the ON
position.
B.
Press the SET button on the Control Panel once.
Fine Adj will appear on the LCD screen.
C.
Press the up arrow button
until the desired
consistency setting is displayed. The higher the
number, the fi rmer the product consistency. The
SECTION 4
MAINTENANCE AND ADJUSTMENTS
control may be set from 1 to 9. The value increases
by 1 each time the up arrow button is pressed.
After the value reaches 9, numbering restarts at
0. The 0 setting cannot be set.
D.
Press the SET button once to save the setting
and return to the current mode display.
4.4
LOCKING THE CONTROL PANEL
(RIGHT SIDE)
The IntelliTec control has a tamper proof mode to prevent
unauthorized use. When set, all buttons on the control
panel are disabled. Follow the instructions below to lock
the control panel
A.
Press and hold the PUSH TO FREEZE button
for at least 5 seconds.
B.
While still holding the PUSH TO FREEZE button,
press the CLEAN button once.
C.
Release both buttons. An asterisk (*) will appear
on the bottom line of the display, indicating that
the control is in the lock out mode.
NOTE:
Repeat steps A, B, and C to unlock the control
panel.
4.5 OBTAINING
READINGS
AND
MODIFYING SETTINGS (SERVICE PERSONNEL
ONLY) (RIGHT SIDE)
Readings and settings on the IntelliTec control are ac-
cessed through the IntelliTec control menu settings.
Locating machine readings and system function settings
are done using the up arrow (
) and left arrow (
) but-
tons on the membrane switch. A printed IntelliTec Menu
Settings sheet is located in the information pouch behind
the header panel.
Figure 4-1 Left Side Product Temperature Control
Figure 4-2 Right Side Membrane Switch