![Stoelting SU444 Air Cooled Operator'S Manual Download Page 22](http://html.mh-extra.com/html/stoelting/su444-air-cooled/su444-air-cooled_operators-manual_1381562022.webp)
16
29.
Press the SEL button. The LCD will read “CutOut
amps” along with the programmed value from the
previous step.
30.
Press the SEL button three times. The LCD will
read “EXITMENU”.
31.
Press the up arrow (
) button to exit the menu.
32.
Adjustment to the control is completed.
E. SERVING PRODUCT
33.
Place the Freezing Cylinder OFF/ON switch in
the ON position.
34.
Press the PUSH TO FREEZE button.
35.
When the product is at 75% consistency, the
display will read “SERVE”.
36.
For normal dispensing, move the spigot handle
fully open.
37.
The machine dispenses product at a reasonable
draw rate. If the machine is overdrawn, the result
is a soft product or a product that will not dispense
at all. If this occurs, allow the machine to run for
approximately 30 seconds before dispensing
more product.
38.
Do not operate the machine when the MIX LOW
message is displayed. Refi ll the mix container
immediately.
NOTE
The right side has a standby and sleep mode. After
a preset number of freezing cycles, it will enter the
standby mode (followed by sleep mode) and remain
there until someone draws product or presses the
PUSH TO FREEZE button. In the sleep mode, the
machine will keep the product below 41°F (7.2°C).
Sleep modes do not take the place of cleaning
and sanitizing. Federal, State, and local regulatory
agencies determine frequency of cleaning and
sanitizing.
3.13 NORMAL FREEZE DOWN AND
OPERATION
Refer to the following procedures to operate both freez-
ing cylinders.
A.
Sanitize immediately before use.
B.
Make sure the Clean/Off/Serve switch (left side)
or the Freezing Cylinder Off/On switch (right side)
is in the OFF position.
C.
Fill the storage container in the cab with at least
2.5 gallons of mix.
D.
Attach the mix inlet probe to the container and
place the container in the refrigerated cab.
E.
Place the mix pump switch in the ON position.
F.
Place a container under the spigot and open it to
allow the mix to fl ush out about 8 ounces (0.23
liters) of sanitizing solution and liquid mix. Close
the spigot.
G.
Open the air bleed valve on the front door by
pressing and holding. Hold the valve open until
the mix level in the freezing cylinder is 1/2” from
the air bleed valve.
H.
Place the Clean/Off/Serve switch (left side) or
the Freezing Cylinder Off/On switch (right side) in
the ON position. On the SU444 right side, make
sure the blender power plug is connected to the
machine and place the Blender Power Off/On
switch in the ON position.
WARNING
Hazardous Moving Parts
Blender shaft and agitator can grab and cause
injury. Do not operate blender without protective
shield or swing splash shield.
I.
On the right side, press the PUSH TO FREEZE
button.
NOTE
After the drive motor starts, there is a 3-second
delay before the compressor starts.
J.
Product will be ready as follows:
On the left side, the product will be ready to serve
after about 3 cycles.
On the right side, the display will read “SERVE
when the product is at 75% consistency.
K.
For normal dispensing, fully open the spigot
handle.
L.
On the SU444 right side, push the spigot handle
to the right to activate the blender. The blender
will operate during or after dispensing product.
M.
Do not operate the right side when the MIX LOW
message is displayed and do not operate the left
side when the mix low indicator light is on. Refi ll
the mix containers immediately.
NOTE
The right side has a standby and sleep mode. After
a preset number of freezing cycles, it will enter the
standby mode (followed by sleep mode) and remain
there until someone draws product or presses the
PUSH TO FREEZE button. In the sleep mode, the
machine will keep the product below 41°F (7.2°C).
Sleep modes do not take the place of cleaning
and sanitizing. Federal, State, and local regulatory
agencies determine frequency of cleaning and
sanitizing.