7
SECTION 3
INITIAL SET-UP AND OPERATION
3.1 OPERATOR’S SAFETY PRECAUTIONS
SAFE OPERATION IS NO ACCIDENT; observe these
rules:
A.
Know the machine. Read and understand the
Operating Instructions.
B.
Notice all warning labels on the machine.
C.
Wear proper clothing. Avoid loose fi tting garments,
and remove watches, rings or jewelry that could
cause a serious accident.
D.
Maintain a clean work area. Avoid accidents by
cleaning up the area and keeping it clean.
E.
Stay alert at all times. Know which switch, push
button or control you are about to use and what
effect it is going to have.
F.
Disconnect power for maintenance. Never
attempt to repair or perform maintenance on the
machine until the main electrical power has been
disconnected.
G.
Do not operate under unsafe operating conditions.
Never operate the machine if unusual or excessive
noise or vibration occurs.
3.2 OPERATING CONTROLS AND INDICATORS
Before operating the machine, it is required that the op-
erator know the function of each operating control. Refer
to Figure 3-1 for the location of the operating controls on
the machine. For the information regarding error codes
displayed on the control panel, refer to the troubleshooting
section of this manual.
A. PUMP SWITCH (BOTH SIDES)
The pump motor switch is the toggle switch located under
the header panel. When the switch is placed in the OFF
position, the pump will not run. When the switch is placed
in the ON position, the pump will run until the preset pres-
sure is reached. It then cycles on and off as product is
drawn to maintain that pressure.
B. SPIGOT SWITCH (BOTH SIDES)
The spigot switch is mounted to the spigot cam assembly
behind the header panel. When the spigot is opened to
dispense product, the spigot switch opens and the “Serve
Mode” begins.
Figure 3-1 SU444 Freezer Controls
Cab Off
Indicator Light
Freezing
Cylinder
Off/On
IntelliTec Control
(See Figure 3-2)
Pump
Off/On
Pump
Off/On
Freezing
Switch
Standby/Serve
Switch
Clean/Off/Serve
Switch
Mix Low
Indicator Light
Main Freezer
Power Off/On
Blender Power
Off/On Circuit
Breaker