16
4.3 TROUBLESHOOTING - AUTO FILL SYSTEM
4.2 TROUBLESHOOTING - CONTINUED
PROBLEM
1
No vent space for free flow of cooling
air.
1
A minimum of 6" of air space on both sides (the
E112 requires 3"). (See Section 2)
2
Condenser is dirty.
2
Clean. (See Section 3)
3
Consistency setting too soft.
3
Turn Consistency Adjustment knob clockwise.
4
Auger is assembled incorrectly.
4
Remove mix, clean, reassemble, sanitize and
freeze down.
5
Auto Fill Pump not operating.
5
See Auto Fill Troubleshooting section.
6
Refrigeration problem.
6
Check system. (Call distributor for service)
1
No mix in hopper.
1
See Auto Fill Troubleshooting section.
2
Drive motor overload tripped.
2
Wait for automatic reset. (If condition
continues, call distributor for service.)
3
Drive belt failure.
3
Replace drive belt.
4
Freeze-up (Auger will not turn).
4
Turn Clean/Off/On switch Off for 15 minutes,
then restart.
1
Worn drive belt.
1
Replace drive belt.
2
Freeze-up (Auger will not turn).
2
Turn Clean/Off/On switch Off for 15 minutes,
then restart.
3
Not tensioned properly.
3
Adjust belt tension
1
Outside surface of rear auger seal is
lubricated.
1
Clean lubricant from outside of rear seal,
lubricate inside of seal and reinstall.
2
Rear seal missing or damaged.
2
Check or replace.
3
Seal o-ring missing, damaged or
installed incorrectly.
3
Check. or replace.
4
Worn or scratched auger shaft.
4
Replace auger shaft.
1
Front door knobs are loose.
1
Tighten knobs.
2
Spigot parts are not lubricated.
2
See Section 3.
3
Chipped or worn spigot o-rings.
3
Replace o-rings.
4
O-rings or spigot installed wrong.
4
Remove spigot and check o-ring.
5
Inner spigot hole in front door nicked or
scratched.
5
Replace front door.
Product does not
dispense.
Front door leaks.
Product is too thin.
Drive belt slipping
or squealing.
Rear auger seal
leaks.
POSSIBLE CAUSE
REMEDY
1
Low water pressure.
1
Verify that there is adequate water pressure at
the inlet fitting (30-50 psi).
2
Restriction or plugged auto fill system. 2
Flush and sanitize the pump and tubing.
3
Empty BIB
3
Replace BIB
1
BIB connector is not connected to the
BIB properly.
1
Check connection and reconnect if necessary.
2
Leak at the connections or in the
tubing.
2
Look for leaks at the connections and bubbles
in the tubing. Tighten clamps and replace
tubing if necessary.
3
Air in the BIB syrup container.
3
Remove the air from the BIB syrup container.
4
Pump is clogged with debris or
particulates.
4
Remove syrup valves and inspect for debris or
improper closing that would interfere with
operation.