![Stoelting E112-LJ Operator'S Manual Download Page 21](http://html1.mh-extra.com/html/stoelting/e112-lj/e112-lj_operators-manual_1381568021.webp)
15
Indication
On
One Blink
Two Blinks
Three Blinks
Conditions
Defrost Mode
Torque is not
met after 20
minutes
Drive current is not sensed
Machine left in clean
mode for over 20
minutes
Self
Correction
N/A
N/A
The machine attempts to sense drive
current with a 3 second pre-stir. If current
is sensed, the machine will return to
normal operation. If current is not sensed,
the machine will wait 7 minutes and try to
sense current with another 3 second pre-
stir. After the third attempt, the
compressor will run on timers.
N/A
Operation
Every 7 minutes
the auger will
run for 90
seconds.
Timers or until
torque switch
remains closed
for 3 seconds.
Timers
Off
Corrective
Action
End Defrost
Mode by turning
Clean/Off/On
switch OFF
then turning it
back ON.
Opening the
spigot will also
end Defrost
Mode.
Contact Service
Technician
Contact Service Technician
Turn Clean/Off/On
switch OFF then turn
it back ON.
SECTION 4
TROUBLESHOOTING
4.1 LIGHT INDICATORS
The machine has two lights that will alert the user if a problem occurs: an ADD MIX light and a Diagnostic Light.
The ADD MIX light will flash to alert the operator to a low mix condition. It does so by monitoring the mix level in the
hopper. When the ADD MIX light is flashing, refill hopper immediately.
The Diagnostic Light will flash if an error occurs. Refer to the chart below for details.
4.2 TROUBLESHOOTING
PROBLEM
1
Power to machine is off.
1
Supply power to machine.
2
Blown fuse or tripped circuit.
2
Replace or reset.
3
Freeze-up (auger will not turn).
3
Turn Clean/Off/On switch Off for 15 minutes,
then restart.
4
Front door not in place.
4
Assemble front door in place.
1
Drive belt failure.
1
Replace drive belt.
2
Consistency temperature setting is too
firm.
2
Turn Consistency Adjustment knob counter-
clockwise.
3
Refrigeration problem.
3
Check system. (Call distributor for service)
Product is too firm.
1
Consistency temperature setting is too
firm.
1
Turn Consistency Adjustment knob counter-
clockwise.
Machine will not
shut off.
Machine does not
run.
POSSIBLE CAUSE