STOBER
7 | Connection
05/2019 | ID 442793.01
59
7.4.15
X22: DC link connection
Terminal X22 is available for the DC link connection of the drive controller.
For setting up the Quick DC-Link, note the information on project configuration in the manual for the SC6 drive controller;
see the chapter
.
Size 0
Terminal
Pin
Designation
Function
1 | 2
1
D−
DC link connection
2
D+
Tab. 68: X22 connection description, size 0
For connecting wiring, observe the terminal specifications in the chapter
Sizes 1 and 2
Terminal
Pin
Designation
Function
1 | 2
1
D−
DC link connection
2
D+
Tab. 69: X22 connection description, sizes 1 and 2
For connecting wiring, observe the terminal specifications in the chapter
.
7.4.16
X101: BE1 – BE4
The binary inputs 1 to 4 are available on terminal X101.
X101 for binary signals
For evaluating binary signals at X101, note the specification for the binary inputs in the technical data of the drive
controller, see the chapter
.
Terminal
Pin
Designation
Function
5|4|3|2|1
1
BE1
Binary inputs
2
BE2
3
BE3
4
BE4
5
DGND
Reference ground; not bridged with X103, pin 5
Tab. 70: X101 connection description for binary signals