11 | Appendix
STOBER
92
05/2019 | ID 442793.01
11.1.8
ISPC 5 -STGCL-7,62
Feature
Line type
Value
Contact spacing
—
7.62 mm
Nominal current at ϑ
amb
= 40 °C
—
CE/UL/CSA:
32 A/35 A/35 A
Max. conductor cross-section
Flexible without end sleeve
6.0 mm²
Flexible with end sleeve without plastic collar
6.0 mm²
Flexible with end sleeve with plastic collar
4.0 mm²
2 conductors, flexible, with double end sleeve with
plastic collar
1.5 mm²
AWG according to UL/CSA
8
Min. conductor cross-section
Flexible without end sleeve
0.2 mm²
Flexible with end sleeve without plastic collar
0.25 mm²
Flexible with end sleeve with plastic collar
0.25 mm²
2 conductors, flexible, with double end sleeve with
plastic collar
0.25 mm²
AWG according to UL/CSA
24
Insulation stripping length
—
15 mm
Tightening torque
—
—
Tab. 106: ISPC 5 -STGCL-7,62 specification
11.1.9
ISPC 16 -ST-10,16
Feature
Line type
Value
Contact spacing
—
10.16 mm
Nominal current at ϑ
amb
= 40 °C
—
CE/UL/CSA:
55 A/66 A/66 A
Max. conductor cross-section
Flexible without end sleeve
16.0 mm²
Flexible with end sleeve without plastic collar
16.0 mm²
Flexible with end sleeve with plastic collar
10.0 mm²
2 conductors, flexible, with double end sleeve with
plastic collar
4.0 mm²
AWG according to UL/CSA
4
Min. conductor cross-section
Flexible without end sleeve
0.75 mm²
Flexible with end sleeve without plastic collar
0.75 mm²
Flexible with end sleeve with plastic collar
0.75 mm²
2 conductors, flexible, with double end sleeve with
plastic collar
0.75 mm²
AWG according to UL/CSA
20
Insulation stripping length
—
18 mm
Tightening torque
—
—
Tab. 107: SPC 16 -ST-10,16 specification