![Stober SC6 Series Commissioning Instructions Download Page 15](http://html.mh-extra.com/html/stober/sc6-series/sc6-series_commissioning-instructions_1381240015.webp)
STOBER
4 | Technical data
05/2019 | ID 442793.01
15
4
Technical data
This chapter contains the technical data for the SC6 drive controller, the DC link connection, the safety technology and the
brakes. Additional technical data on the drive controller and accessories can be found in the SC6 drive controller manual;
see the chapter
.
4.1
Drive controllers
The following chapters contain specifications for the electrical data, dimensions and weight of the drive controller.
4.1.1
General technical data
The following specifications apply to all drive controller types.
Device features
Protection class of the device
IP20
Protection class of the installation space
At least IP54
Radio interference suppression
Integrated line filter in accordance with EN 61800-3:2012, interference
emission class C3
Overvoltage category
III in accordance with EN 61800-5-1:2008
Test symbols
Tab. 2: Device features
Transport and storage conditions
Storage/
transport temperature
−20 °C to +70 °C
Maximum change: 20 K/h
Relative humidity
Maximum relative humidity 85%, non-condensing
Vibration (transport) in accordance with
DIN EN 60068-2-6
5 Hz ≤ f ≤ 9 Hz: 3.5 mm
9 Hz ≤ f ≤ 200 Hz: 10 m/s²
200 Hz ≤ f ≤ 500 Hz: 15 m/s²
Fall height for freefall
1
Weight < 100 kg
in accordance with DIN EN 61800-2
(or DIN EN 60721-3-2:1997, class 2M1)
0.25 m
Tab. 3: Transport and storage conditions
Operating conditions
Surrounding temperature during
operation
0 °C to 45 °C with nominal data
45 °C to 55 °C with derating −2.5% / K
Relative humidity
Maximum relative humidity 85%, non-condensing
Installation altitude
0 m to 1000 m above sea level without restrictions
1000 m to 2000 m above sea level with −1.5%/100 m derating
Pollution degree
Pollution degree 2 in accordance with EN 50178
Ventilation
Installed fan
Vibration (operation) in accordance with
DIN EN 60068-2-6
5 Hz ≤ f ≤ 9 Hz: 0.35 mm
9 Hz ≤ f ≤ 200 Hz: 1 m/s²
Tab. 4: Operating conditions
1
Only valid for components in original packaging