Appendix G. ODU installation
The ODU comprises the antenna with feed-horn and mounting structure, and a transceiver that contains
the LNB integrated with OMT, Tx-reject filter, and the transmitter (BUC). If the STM SatLink 4033/4035
transceiver is not used, the OMT, LNB and BUC may be supplied as two or three separate units. Two
cables with F-connectors, one for Tx and one for Rx are connecting the ODU to the IDU.
Figure 19: STM SatLink 4033/4035 Configuration
G.1 Assembly of SatLink 403x transceiver to feedhorn
The STM SatLink 403x is supplied with 6 pcs of UNC 6/32 for connection to the antenna flange. The
parts are shown in the picture below. Please refer to Appendix I for information of how to connect the
STM SatLink 403x to antenna feed horn interfaces with 6 or 8 M4 screws.
Figure 20: SatLink 4033/4035 and screws for mounting feed horn
Transceiver
mounted
directly on
antenna
feed
Antenna
Feed Horn
Antenna
Reflector