Copyright © 2006 – STM Norway AS
Publication no. 101557, Rev. T, November 3
th
, 2006
Page 14
3.5.2 Ethernet connection to a Local Area Network (LAN)
The STM SatLink Terminal may be connected to a single PC or to a network via the RJ-45 Ethernet jack
on the back panel.
•
Plug one end of the Ethernet cable into the RJ-45 jack on the back panel.
•
Plug the other end of the Ethernet cable into the RJ-45 jack a Local Area Network (LAN) device such
as an Ethernet hub, switch or router, according to its manufacturer’s instructions.
For the STM SatLink 1900 and 1901, toggle the back panel push button to set Ethernet HUB or NODE
mode. Toggle to NODE when connecting to an Ethernet switch or an Ethernet hub and toggle to HUB
when connecting to a single PC.
For the STM SatLink 1000 and 1910 there is no push button on the back panel as Ethernet HUB or
NODE mode will be auto-detected and the correct mode chosen automatically.
3.5.3 Mains connection
The STM SatLink 1900/1901/1910 models have internal power supply and consequently are connected
directly to a 110/230 VAC 50/60Hz outlet using a standard 230 VAC mains cord.
3.5.4 Power supply
The STM SatLink 1000 has an external power supply that is connected to a 110/230 VAC 50/60Hz outlet
using a standard mains cord.
The STM SatLink 1000 must only be connected to the external power supply that is
approved by STM , PN 104170 (LEI-S2425D / Model No. STD-2425). Use of another power
supply will void warranty.