21
AFTER SALES SUPPORT
1300 886 649
AUS
MODEL: STR-SGC60 PRODUCT CODE: 700793 04/2020
Installation (Cont.)
Gas adjustment (conversion for use with ULPG)
This cooktop is fitted out for use with Natural Gas (NG). If it is to be used with
Universal Liquefied Petroleum gas (ULPG), the burners have to be converted.
IMPORTANT:
Before starting the conversion, make sure all gas is
switched off (and preferably disconnected from the appliance) and the
electrical power has been disconnected.
Changing the injectors of the burners
• Remove the pan supports, flame
spreaders and burner caps.
• Unscrew the injector (Fig. 12) using a
7mm box spanner and replace it with the
stipulated injector for the new gas supply
(see Table 1 below).
• Carefully reassemble all the components;
in particular you should make sure that the
burner crown is correctly placed on the
burner.
• After the injectors are replaced, it is
advisable to firmly tighten the injector in place.
•
IMPORTANT:
The minimum flow adjustment process must be completed
before the appliance is next used (see page 22).
Table 1
Regulated for
NATURAL GAS
ULPG
Injection
∅
(mm)
MJ/h
Gas
Pressure
Injection
∅
(mm)
MJ/h
Gas
Pressure
Rapid
1.50
10.8
1.0 kPa
0.88
10.8
2.75 kPa
Semirapid
1.12
6.3
0.68
6.3
Auxiliary
0.90
4.0
0.56
4.0
Total
27.4
27.4
Fig. 12