Safety
Safety tests
Measuring the battery’s insulation
resistance
NOTE
Nominal battery voltage < test voltage < 500
V.
– Measure the insulation resistance with a
suitable measuring device.
The insulation resistance can be considered
sufficient if it measures at least 500 /V for the
nominal battery voltage against ground.
– Contact the authorised service centre.
Measuring the insulation resistance of
the electrical system
NOTE
Nominal battery voltage < test voltage < 500
V.
– Ensure that all voltage sources have been
disconnected from the circuit to be tested.
– Measure the insulation resistance with a
suitable measuring device.
The insulation resistance can be considered
sufficient if it measures at least 1000 /V for
the nominal battery voltage against ground.
– Contact the authorised service centre.
38
55048011501 EN - 12/2015
Summary of Contents for RX50-10
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 24: ...1 Foreword Environmental considerations 12 55048011501 EN 12 2015 ...
Page 25: ...2 Introduction ...
Page 37: ...3 Safety ...
Page 60: ...3 Safety Emissions 48 55048011501 EN 12 2015 ...
Page 61: ...4 Overviews ...
Page 63: ...Overviews 4 General view of truck 55048011501 EN 12 2015 51 ...
Page 75: ...Overviews 4 Operating devices and display elements 55048011501 EN 12 2015 63 ...
Page 79: ...5 Operation ...
Page 305: ...6 Maintenance ...
Page 308: ...6 Maintenance General maintenance information 296 55048011501 EN 12 2015 ...
Page 312: ...6 Maintenance General maintenance information 300 55048011501 EN 12 2015 ...
Page 348: ...6 Maintenance 1000 hour maintenance Annual maintenance 336 55048011501 EN 12 2015 ...
Page 349: ...7 Technical data ...
Page 373: ......
Page 374: ...STILL GmbH 55048011501 EN 12 2015 ...